Merge pull request #1037 from ianmcorvidae/patch-2
Update home-assistant.mdx to add device_class and use this.state
This commit is contained in:
commit
c3fbcaa634
|
@ -52,7 +52,7 @@ sensor:
|
|||
value_json.payload.temperature is not defined %}
|
||||
{{ (value_json.payload.voltage | float) | round(2) }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_1_battery_voltage') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
unit_of_measurement: "Volts"
|
||||
# Telemetry packets come in two flavors: The default node telemetry, and the I2C sensor data.
|
||||
|
@ -66,8 +66,9 @@ sensor:
|
|||
{% if value_json.from == 4038675309 and value_json.payload.battery_level is defined %}
|
||||
{{ (value_json.payload.battery_level | float) | round(2) }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_1_battery_percent') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
device_class: "battery"
|
||||
unit_of_measurement: "%"
|
||||
|
||||
- name: "Node 1 ChUtil"
|
||||
|
@ -78,7 +79,7 @@ sensor:
|
|||
{% if value_json.from == 4038675309 and value_json.payload.channel_utilization is defined %}
|
||||
{{ (value_json.payload.channel_utilization | float) | round(2) }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_1_chutil') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
unit_of_measurement: "%"
|
||||
|
||||
|
@ -90,7 +91,7 @@ sensor:
|
|||
{% if value_json.from == 4038675309 and value_json.payload.air_util_tx is defined %}
|
||||
{{ (value_json.payload.air_util_tx | float) | round(2) }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_1_airutiltx') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
unit_of_measurement: "%"
|
||||
|
||||
|
@ -109,9 +110,12 @@ sensor:
|
|||
{% if value_json.from == 4038675309 and value_json.payload.temperature is defined %}
|
||||
{{ (((value_json.payload.temperature | float) * 1.8) +32) | round(2) }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_1_temperature') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
device_class: "temperature"
|
||||
unit_of_measurement: "F"
|
||||
# With device_class: "temperature" set, make sure to use the configured unit for temperature in your HA instance.
|
||||
# If you don't, then non-temperature messages will change the value of this sensor by reinterpreting the current state with the wrong unit, unless you account for it.
|
||||
# For Celsius use: {{ (value_json.payload.temperature | float) | round(1) }}
|
||||
# For Fahrenheit use: {{ (((value_json.payload.temperature | float) * 1.8) +32) | round(2) }}
|
||||
|
||||
|
@ -123,8 +127,9 @@ sensor:
|
|||
{% if value_json.from == 4038675309 and value_json.payload.relative_humidity is defined %}
|
||||
{{ (value_json.payload.relative_humidity | float) | round(2) }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_1_humidity') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
device_class: "humidity"
|
||||
unit_of_measurement: "%"
|
||||
|
||||
- name: "Node 1 Pressure"
|
||||
|
@ -135,9 +140,12 @@ sensor:
|
|||
{% if value_json.from == 4038675309 and value_json.payload.barometric_pressure is defined %}
|
||||
{{ (value_json.payload.barometric_pressure | float) | round(2) }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_1_pressure') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
device_class: "pressure"
|
||||
unit_of_measurement: "hPa"
|
||||
# With device_class: "pressure" set, make sure to use the configured unit for pressure in your HA instance.
|
||||
# For psi use: {{ ((value_json.payload.barometric_pressure | float) / 68.9475729) | round(2) }}
|
||||
|
||||
- name: "Node 1 Gas Resistance"
|
||||
unique_id: "node_1_gas_resistance"
|
||||
|
@ -147,7 +155,7 @@ sensor:
|
|||
{% if value_json.from == 4038675309 and value_json.payload.gas_resistance is defined %}
|
||||
{{ (value_json.payload.gas_resistance | float) | round(2) }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_1_gas_resistance') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
unit_of_measurement: "MOhms"
|
||||
```
|
||||
|
@ -164,7 +172,7 @@ sensor:
|
|||
{% if value_json.from == 4038675309 and value_json.payload.text is defined %}
|
||||
{{ value_json.payload.text }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_1_messages') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
```
|
||||
|
||||
|
@ -190,7 +198,7 @@ Copy and paste these entities then change `name`, `unique_id`, `from`, and `stat
|
|||
{% if value_json.from == 695318008 and value_json.payload.text is defined %}
|
||||
{{ value_json.payload.text }}
|
||||
{% else %}
|
||||
{{ states('sensor.node_2_messages') }}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
```
|
||||
|
||||
|
|
Loading…
Reference in a new issue