--- id: telemetry-module title: Telemetry sidebar_label: Telemetry sidebar_position: 6 --- ## About The Telemetry Module will allow nodes to send a specific message with information from connected sensors. Currently supported sensors are `BME280`, `BME680`, `DHT11`, `DHT12`, `DHT21`, `DHT22`, Dallas 1-wire `DS18B20`, and `MCP9808`. The preferred setup is using I2C, so the `telemetry_module_sensor_pin` may not be needed. ## Usage Notes For basic usage, start with: ```shell telemetry_module_enabled = 1 telemetry_module_screen_enabled = 1 ``` Depending on which pin your sensor is connected to, set it accordingly: ```shell telemetry_module_sensor_pin = 13 ``` :::note The device must be restarted after the settings have been changed for the module to take effect. ::: ## Hardware The sensors can be wired differently, here's one example for sensor DS18B20 https://randomnerdtutorials.com/esp32-ds18b20-temperature-arduino-ide ## Example of T-LoraV1 with DHT22 temperature sensor Setup of a T-LoraV1 with DHT22 temperature sensor. [](/img/hardware/lora_v1_with_DHT22.jpg) Requirements: - T-LoraV1 (but any esp32 should work, just be sure to double check which GPIO to use) - DHT22 sensor - 10 Kohm resistor (optional, but recommended) - breadboard (optional) - two red wires (could be a different color, but 5V is typically red) - two yellow wires for GPIO (could be a different color) - one black wire (could be a different color, but GROUND is typically black) Steps: - disconnect power/battery - connect black wire from GROUND to "-" on the DHT22 - connect yellow wire from middle PIN to a row on bread board - connect red wire from 5V to a row on breadboard - connect resistor between red and yellow rows - connect red wire from row with red to "+" on DHT22 - connect yellow wire from yellow row to GPIO on device (ex: GPIO21) - double check the cabling (if you get it wrong, you can damage the device and/or the DHT22 sensor) - plug in device - configure the device: ```shell meshtastic --set telemetry_module_measurement_enabled true --set telemetry_module_screen_enabled true --set telemetry_module_update_interval 15 --set telemetry_module_display_farenheit true --set telemetry_module_sensor_type DHT22 --set telemetry_module_sensor_pin 21 ``` :::tip You can change the values above to suit your needs. The commands can be run one at a time or in a group as show above. ::: - reboot/reset the device (press the RST button or unplug/plug in the device) - when the device boots it should say "Telemetry" and it may show the sensor data - if "no data", then triple check the wiring - if still "no data", run: ```shell meshtastic --info ``` and verify the the `telemetry_module_sensor_type and` `telemetry_module_sensor_pin` ## Example of T-LoraV1 with Dallas DS18B20 temperature sensor Setup of a T-LoraV1 with DS18B20 temperature sensor. [](/img/hardware/lora_v1_with_DS18B20.jpg) Requirements: - T-LoraV1 (but any esp32 should work, just be sure to double check which GPIO to use) - DS18B20 sensor - 10 Kohm resistor (optional, but recommended) - breadboard (optional) - two red wires (could be a different color, but 5V is typically red) - two yellow wires for GPIO (could be a different color) - one black wire (could be a different color, but GROUND is typically black) Steps: - disconnect power/battery - connect black wire from GROUND to "-" on the DS18B20 - connect yellow wire from DAT pin to a row on bread board - connect red wire from 5V to a row on breadboard - connect resistor between red and yellow rows - connect red wire from row with red to "VCC" on DS18B20 - connect yellow wire from yellow row to GPIO on device (ex: GPIO21) - double check the cabling (if you get it wrong, you can damage the device and/or the sensor) - plug in device - configure the device: ```shell meshtastic --set telemetry_module_measurement_enabled true --set telemetry_module_screen_enabled true --set telemetry_module_update_interval 15 --set telemetry_module_display_farenheit true --set telemetry_module_sensor_type DS18B20 --set telemetry_module_sensor_pin 21 ``` :::tip You can change the values above to suit your needs. The commands can be run one at a time or in a group as show above. ::: - reboot/reset the device (press the RST button or unplug/plug in the device) - when the device boots it should say "Telemetry" and it may show the sensor data - if "no data", then triple check the wiring - if still "no data", run: ```shell meshtastic --info ``` and verify the the `telemetry_module_sensor_type` and `telemetry_module_sensor_pin` ## Example of RAK 4631 with Environment Sensor Setup of a RAK 4631 with Environment Sensor [](/img/hardware/rak/RAK4631_with_EnvSensor.jpg) Requirements: - RAK4631 - Environment Sensor Steps: - configure the device: ```shell meshtastic --set telemetry_module_measurement_enabled true --set telemetry_module_screen_enabled true --set telemetry_module_update_interval 15 --set telemetry_module_display_farenheit true --set telemetry_module_sensor_type 6 ``` :::tip You can change the values above to suit your needs. The commands can be run one at a time or in a group as show above. ::: - reboot/reset the device (press the button or unplug/plug in the device) - when the device boots it should say "Telemetry" and it may show the sensor data - if still "no data", run: ```shell meshtastic --info ``` and verify the the `telemetry_module_sensor_type` ## Configuration Configuration details are available on the [Device Settings](/docs/settings) pages. Configuring the Telemetry Module requires configuring the following modules: - [Telemetry Module](/docs/settings/modules/telemetry-module) ## Known Problems - No default configuration values are currently set, so this must be done when enabling the module.