* initial devices.json * initial hardware components * testing page at /docs/hardware/supported/template * WIP Changes * Home page work & updates * Fix build * Fix external link button * Setup linting * rename, cleanup & lint * seperate lint cmd for now Co-authored-by: Foster Irwin <foster@jfirwin.com> Co-authored-by: Sacha Weatherstone <sachaw100@hotmail..om>
226 lines
7.1 KiB
Plaintext
226 lines
7.1 KiB
Plaintext
---
|
|
id: telemetry-module
|
|
title: Telemetry
|
|
sidebar_label: Telemetry
|
|
---
|
|
import PluginModule from '@site/docs/_blocks/_plugin_module.mdx';
|
|
|
|
<PluginModule name="telemetry_" rename="environmental_measurment_"/>
|
|
|
|
## About
|
|
|
|
The Telemetry Module will allow nodes to send a specific message with information from connected sensors. Currently supported sensors are `BME280`, `BME680`, `DHT11`, `DHT12`, `DHT21`, `DHT22`, Dallas 1-wire `DS18B20`, and `MCP9808`.
|
|
|
|
The preferred setup is using I2C, so the `telemetry_module_sensor_pin` may not be needed.
|
|
|
|
## Configuration
|
|
|
|
These are the settings that can be configured.
|
|
|
|
telemetry_module_enabled
|
|
Is the module enabled?
|
|
|
|
0 = Disabled (Default)
|
|
1 = Enabled
|
|
|
|
telemetry_module_screen_enabled
|
|
Show received sensor readings on device screen.
|
|
|
|
0 = Disabled (Default)
|
|
1 = Enabled
|
|
|
|
telemetry_module_read_error_count_threshold
|
|
Error count threshold for failed sensor readings.
|
|
|
|
Default = 0
|
|
|
|
preferences.telemetry_module_update_interval
|
|
How often (in seconds) should sensor readings be broadcasted?
|
|
|
|
Default = 0
|
|
|
|
telemetry_module_recovery_interval
|
|
For how long should we wait (in seconds) before trying to read sensors again upon exceeded error threshold?
|
|
|
|
Default = 0
|
|
|
|
telemetry_module_display_fahrenheit
|
|
Should temperature readings be converted to fahrenheit?
|
|
|
|
0 = Disabled (Default)
|
|
1 = Enabled
|
|
|
|
telemetry_module_sensor_type
|
|
What sensor is connected?
|
|
|
|
0 = DHT11 (Default)
|
|
1 = Dallas 1-wire DS18B20
|
|
2 = DHT12
|
|
3 = DHT21
|
|
4 = DHT22
|
|
5 = BME280
|
|
6 = BME680
|
|
7 = MCP9808
|
|
|
|
telemetry_module_sensor_pin
|
|
Which pin is the sensor connected to?
|
|
|
|
Default = 0
|
|
|
|
## Usage Notes
|
|
|
|
For basic usage, start with:
|
|
|
|
```shell
|
|
telemetry_module_enabled = 1
|
|
|
|
telemetry_module_screen_enabled = 1
|
|
```
|
|
|
|
Depending on which pin your sensor is connected to, set it accordingly:
|
|
|
|
```shell
|
|
telemetry_module_sensor_pin = 13
|
|
```
|
|
|
|
:::note
|
|
The device must be restarted after the settings have been changed for the module to take effect.
|
|
:::
|
|
|
|
## Hardware
|
|
|
|
The sensors can be wired differently, here's one example for sensor DS18B20 https://randomnerdtutorials.com/esp32-ds18b20-temperature-arduino-ide
|
|
|
|
## Example of T-LoraV1 with DHT22 temperature sensor
|
|
|
|
Setup of a T-LoraV1 with DHT22 temperature sensor.
|
|
|
|
[<img src="T-LoraV1 with DHT22" src="/img/hardware/lora_v1_with_DHT22.jpg" style={{zoom:'25%'}} />](/img/hardware/lora_v1_with_DHT22.jpg)
|
|
|
|
Requirements:
|
|
|
|
- T-LoraV1 (but any esp32 should work, just be sure to double check which GPIO to use)
|
|
- DHT22 sensor
|
|
- 10 Kohm resistor (optional, but recommended)
|
|
- breadboard (optional)
|
|
- two red wires (could be a different color, but 5V is typically red)
|
|
- two yellow wires for GPIO (could be a different color)
|
|
- one black wire (could be a different color, but GROUND is typically black)
|
|
|
|
Steps:
|
|
|
|
- disconnect power/battery
|
|
- connect black wire from GROUND to "-" on the DHT22
|
|
- connect yellow wire from middle PIN to a row on bread board
|
|
- connect red wire from 5V to a row on breadboard
|
|
- connect resistor between red and yellow rows
|
|
- connect red wire from row with red to "+" on DHT22
|
|
- connect yellow wire from yellow row to GPIO on device (ex: GPIO21)
|
|
- double check the cabling (if you get it wrong, you can damage the device and/or the DHT22 sensor)
|
|
- plug in device
|
|
- configure the device:
|
|
|
|
```shell
|
|
meshtastic --set telemetry_module_measurement_enabled true --set telemetry_module_screen_enabled true --set telemetry_module_update_interval 15 --set telemetry_module_display_farenheit true --set telemetry_module_sensor_type DHT22 --set telemetry_module_sensor_pin 21
|
|
```
|
|
|
|
:::tip
|
|
You can change the values above to suit your needs. The commands can be run one at a time or in a group as show above.
|
|
:::
|
|
|
|
- reboot/reset the device (press the RST button or unplug/plug in the device)
|
|
- when the device boots it should say "Telemetry" and it may show the sensor data
|
|
- if "no data", then triple check the wiring
|
|
- if still "no data", run:
|
|
|
|
```shell
|
|
meshtastic --info
|
|
```
|
|
|
|
and verify the the `telemetry_module_sensor_type and` `telemetry_module_sensor_pin`
|
|
|
|
## Example of T-LoraV1 with Dallas DS18B20 temperature sensor
|
|
|
|
Setup of a T-LoraV1 with DS18B20 temperature sensor.
|
|
|
|
[<img src="T-LoraV1 with DS18B20" src="/img/hardware/lora_v1_with_DS18B20.jpg" style={{zoom:'25%'}} />](/img/hardware/lora_v1_with_DS18B20.jpg)
|
|
|
|
Requirements:
|
|
|
|
- T-LoraV1 (but any esp32 should work, just be sure to double check which GPIO to use)
|
|
- DS18B20 sensor
|
|
- 10 Kohm resistor (optional, but recommended)
|
|
- breadboard (optional)
|
|
- two red wires (could be a different color, but 5V is typically red)
|
|
- two yellow wires for GPIO (could be a different color)
|
|
- one black wire (could be a different color, but GROUND is typically black)
|
|
|
|
Steps:
|
|
|
|
- disconnect power/battery
|
|
- connect black wire from GROUND to "-" on the DS18B20
|
|
- connect yellow wire from DAT pin to a row on bread board
|
|
- connect red wire from 5V to a row on breadboard
|
|
- connect resistor between red and yellow rows
|
|
- connect red wire from row with red to "VCC" on DS18B20
|
|
- connect yellow wire from yellow row to GPIO on device (ex: GPIO21)
|
|
- double check the cabling (if you get it wrong, you can damage the device and/or the sensor)
|
|
- plug in device
|
|
- configure the device:
|
|
|
|
```shell
|
|
meshtastic --set telemetry_module_measurement_enabled true --set telemetry_module_screen_enabled true --set telemetry_module_update_interval 15 --set telemetry_module_display_farenheit true --set telemetry_module_sensor_type DS18B20 --set telemetry_module_sensor_pin 21
|
|
```
|
|
|
|
:::tip
|
|
You can change the values above to suit your needs. The commands can be run one at a time or in a group as show above.
|
|
:::
|
|
|
|
- reboot/reset the device (press the RST button or unplug/plug in the device)
|
|
- when the device boots it should say "Telemetry" and it may show the sensor data
|
|
- if "no data", then triple check the wiring
|
|
- if still "no data", run:
|
|
|
|
```shell
|
|
meshtastic --info
|
|
```
|
|
|
|
and verify the the `telemetry_module_sensor_type` and `telemetry_module_sensor_pin`
|
|
|
|
## Example of RAK 4631 with Environment Sensor
|
|
|
|
Setup of a RAK 4631 with Environment Sensor
|
|
|
|
[<img src="RAK4631_with_EnvSensor" src="/img/hardware/rak/RAK4631_with_EnvSensor.jpg" style={{zoom:'25%'}} />](/img/hardware/rak/RAK4631_with_EnvSensor.jpg)
|
|
|
|
Requirements:
|
|
|
|
- RAK4631
|
|
- Environment Sensor
|
|
|
|
Steps:
|
|
|
|
- configure the device:
|
|
|
|
```shell
|
|
meshtastic --set telemetry_module_measurement_enabled true --set telemetry_module_screen_enabled true --set telemetry_module_update_interval 15 --set telemetry_module_display_farenheit true --set telemetry_module_sensor_type 6
|
|
```
|
|
|
|
:::tip
|
|
You can change the values above to suit your needs. The commands can be run one at a time or in a group as show above.
|
|
:::
|
|
|
|
- reboot/reset the device (press the button or unplug/plug in the device)
|
|
- when the device boots it should say "Telemetry" and it may show the sensor data
|
|
- if still "no data", run:
|
|
|
|
```shell
|
|
meshtastic --info
|
|
```
|
|
|
|
and verify the the `telemetry_module_sensor_type`
|
|
|
|
## Known Problems
|
|
|
|
- No default configuration values are currently set, so this must be done when enabling the module.
|