id: telemetry
|
|
title: Telemetry Module Configuration
|
|
sidebar_label: Telemetry
|
|
---
|
|
|
|
import Tabs from '@theme/Tabs';
|
|
import TabItem from '@theme/TabItem';
|
|
|
|
The Telemetry Module provides two types of data over the mesh. Device metrics (Battery Level, Voltage, Channel Utilization and Airtime) from your meshtastic device and Environement Metrics from attached I2C sensors.
|
|
|
|
Supported sensors connected to the I2C bus of the device will be automattically detected at startup. Environement Telemetry must be enabled for them to be instrumented and their readings sent over the mesh.
|
|
|
|
The telemetry module config options are: Device Metrics Update Interval, Environment Metrics Update Interval, Environement Telemetry Enabled, Show on Device Screen, and Display Fahrenheit.
|
|
|
|
### Currently Supported Sensor Types
|
|
|
|
| Sensor | Data Points |
|
|
| :-----: | :-----------------------------------------------------------: |
|
|
| BMP280 | Temperature and barometric pressure |
|
|
| BME280 | Temperature, barometric pressure and humidity |
|
|
| BME680 | Temperature, barometric pressure, humidity and air resistance |
|
|
| MCP9808 | Temperature |
|
|
| INA260 | Current and Voltage |
|
|
| INA219 | Current and Voltage |
|
|
|
|
## Telemetry Module Config Values
|
|
|
|
## Update Intervals
|
|
|
|
### Device Metrics Update Interval
|
|
|
|
How often we should send Device Metrics over the mesh.
|
|
|
|
Default is every 5 minutes.
|
|
|
|
### Environment Metrics Update Interval
|
|
|
|
How often we should send Environment(Sensor) Metrics over the mesh.
|
|
|
|
Default is every 5 minutes.
|
|
|
|
## Sensor options
|
|
|
|
### Environment Telemetry Enabled
|
|
|
|
Enable the Environment Telemetry (Sensors)
|
|
|
|
### Show on device screen
|
|
|
|
Show the Telemetry Module on-device display.
|
|
|
|
### Display Fahrenheit
|
|
|
|
The sensor is always read in Celsius, but the user can opt to view the temperature display in Fahrenheit using this setting.
|
|
|
|
Default is off
|
|
|
|
## Device Config Client Availability
|
|
|
|
<Tabs
|
|
groupId="settings"
|
|
defaultValue="apple"
|
|
values={[
|
|
{label: 'Android', value: 'android'},
|
|
{label: 'Apple', value: 'apple'},
|
|
{label: 'CLI', value: 'cli'},
|
|
{label: 'Flasher', value: 'flasher'},
|
|
{label: 'Web', value: 'web'},
|
|
]}>
|
|
<TabItem value="android">
|
|
|
|
:::info
|
|
Telemetry Module config is not available for Android.
|
|
:::
|
|
|
|
</TabItem>
|
|
<TabItem value="apple">
|
|
|
|
:::info
|
|
All telemetry module config options are available on iOS, iPadOS and macOS at Settings > Module Configuration > Telemetry.
|
|
|
|
:::
|
|
|
|
</TabItem>
|
|
<TabItem value="cli">
|
|
|
|
No telemetry module config options are available in the python CLI. Example commands are below:
|
|
|
|
## Settings
|
|
|
|
| Setting | Acceptable Values | Default |
|
|
| :-----------------------------------------------------: | :-----------------: | :-----: |
|
|
| telemetry_module_device_update_interval | `integer` (seconds) | `0` |
|
|
| telemetry_module_environment_display_fahrenheit | `true`, `false` | `false` |
|
|
| telemetry_module_environment_measurement_enabled | `true`, `false` | `false` |
|
|
| telemetry_module_environment_screen_enabled | `true`, `false` | `0` |
|
|
| telemetry_module_environment_update_interval | `integer` (seconds) | `0` |
|
|
|
|
```shell title="Set module update intervals (Default of 0 is 5 Minutes)"
|
|
meshtastic --set telemetry_module_device_update_interval 0
|
|
// Device Metrics Two Minutes
|
|
meshtastic --set telemetry_module_device_update_interval 120
|
|
// Environment Metrics Two Minutes
|
|
meshtastic --set telemetry_module_environment_update_interval 120
|
|
````
|
|
|
|
```shell title="Enable/Disable Environment Module"
|
|
meshtastic --set telemetry_module_environment_measurement_enabled true
|
|
meshtastic --set telemetry_module_environment_measurement_enabled false
|
|
```
|
|
|
|
```shell title="Enable/Disable on device screen"
|
|
meshtastic --set telemetry_module_environment_screen_enabled true
|
|
meshtastic --set telemetry_module_environment_screen_enabled false
|
|
```
|
|
|
|
```shell title="Enable / Disable Display Farenheit"
|
|
meshtastic --set telemetry_module_environment_display_fahrenheit true
|
|
meshtastic --set telemetry_module_environment_display_fahrenheit false
|
|
````
|
|
|
|
</TabItem>
|
|
<TabItem value="flasher">
|
|
|
|
:::info
|
|
No telemetry module config options are available in the Flasher.
|
|
:::
|
|
|
|
</TabItem>
|
|
<TabItem value="web">
|
|
|
|
:::info
|
|
No telemetry module config options are available in the Web UI.
|
|
:::
|
|
|
|
</TabItem>
|
|
</Tabs>
|
|
|
|
## Examples
|
|
|
|
### RAK 4631 with Environment Sensor
|
|
|
|
Setup of a RAK 4631 with Environment Sensor
|
|
|
|
[<img src="RAK4631_with_EnvSensor" src="/img/hardware/rak/RAK4631_with_EnvSensor.jpg" style={{zoom:'25%'}} />](/img/hardware/rak/RAK4631_with_EnvSensor.jpg)
|
|
|
|
Requirements:
|
|
|
|
- RAK4631
|
|
- Environment Sensor
|
|
|
|
Steps:
|
|
|
|
- configure the device:
|
|
|
|
```shell
|
|
meshtastic --set telemetry_module_measurement_enabled true --set telemetry_module_screen_enabled true --set telemetry_module_display_farenheit true
|
|
```
|
|
|
|
:::tip
|
|
You can change the values above to suit your needs. The commands can be run one at a time or in a group as show above.
|
|
:::
|
|
|
|
- Reboot/reset the device (press the button or unplug/plug in the device)
|
|
- When the device boots it should say "Telemetry" and it may show the sensor data
|
|
- If this does not appear to have any effects, run:
|
|
|
|
```shell
|
|
meshtastic --noproto
|
|
```
|
|
|
|
And examine the serial logs for Telemetry diagnostic information.
|
|
|