node_exporter/docs/node-mixin/rules/rules.libsonnet

116 lines
4.1 KiB
Plaintext
Raw Normal View History

{
prometheusRules+:: {
groups+: [
{
name: 'node-exporter.rules',
rules: [
{
// This rule gives the number of CPUs per node.
record: 'instance:node_num_cpu:sum',
expr: |||
count without (cpu) (
count without (mode) (
node_cpu_seconds_total{%(nodeExporterSelector)s}
)
)
||| % $._config,
},
{
// CPU utilisation is % CPU is not idle.
record: 'instance:node_cpu_utilisation:rate1m',
expr: |||
1 - avg without (cpu, mode) (
rate(node_cpu_seconds_total{%(nodeExporterSelector)s, mode="idle"}[1m])
)
||| % $._config,
},
{
// This is CPU saturation: 1min avg run queue length / number of CPUs.
// Can go over 1.
// TODO: There are situation where a run queue >1/core is just normal and fine.
// We need to clarify how to lead this metric and if its usage is helpful at all.
record: 'instance:node_load1_per_cpu:ratio',
expr: |||
(
node_load1{%(nodeExporterSelector)s}
/
instance:node_num_cpu:sum{%(nodeExporterSelector)s}
)
||| % $._config,
},
{
// Memory utilisation per node, normalized by per-node memory
record: 'instance:node_memory_utilisation:ratio',
expr: |||
1 - (
node_memory_MemAvailable_bytes{%(nodeExporterSelector)s}
/
node_memory_MemTotal_bytes{%(nodeExporterSelector)s}
)
||| % $._config,
},
{
record: 'instance:node_memory_swap_io_pages:rate1m',
expr: |||
(
rate(node_vmstat_pgpgin{%(nodeExporterSelector)s}[1m])
+
rate(node_vmstat_pgpgout{%(nodeExporterSelector)s}[1m])
)
||| % $._config,
},
{
// Disk utilisation (seconds spent, 1 second rate)
record: 'instance_device:node_disk_io_time_seconds:rate1m',
expr: |||
rate(node_disk_io_time_seconds_total{%(nodeExporterSelector)s, %(diskDeviceSelector)s}[1m])
||| % $._config,
},
{
// Disk saturation (weighted seconds spent, 1 second rate)
record: 'instance_device:node_disk_io_time_weighted_seconds:rate1m',
expr: |||
rate(node_disk_io_time_weighted_seconds_total{%(nodeExporterSelector)s, %(diskDeviceSelector)s}[1m])
||| % $._config,
},
// TODO: For the following rules, consider configurable filtering to exclude more network
// device names than just "lo".
{
record: 'instance:node_network_receive_bytes:rate1m',
expr: |||
sum without (device) (
rate(node_network_receive_bytes_total{%(nodeExporterSelector)s, device!="lo"}[1m])
)
||| % $._config,
},
{
record: 'instance:node_network_transmit_bytes:rate1m',
expr: |||
sum without (device) (
rate(node_network_transmit_bytes_total{%(nodeExporterSelector)s, device!="lo"}[1m])
)
||| % $._config,
},
// TODO: Find out if those drops ever happen on modern switched networks.
{
record: 'instance:node_network_receive_drop:rate1m',
expr: |||
sum without (device) (
rate(node_network_receive_drop_total{%(nodeExporterSelector)s, device!="lo"}[1m])
)
||| % $._config,
},
{
record: 'instance:node_network_transmit_drop:rate1m',
expr: |||
sum without (device) (
rate(node_network_transmit_drop_total{%(nodeExporterSelector)s, device!="lo"}[1m])
)
||| % $._config,
},
],
},
],
},
}