mirror of
https://github.com/prometheus/node_exporter.git
synced 2024-12-26 22:19:44 -08:00
Merge pull request #1449 from prometheus/beorn7/mixin3
node-mixin: Make the severity of "critical" alerts configurable
This commit is contained in:
commit
0f38d680b4
|
@ -37,7 +37,7 @@
|
|||
||| % $._config,
|
||||
'for': '1h',
|
||||
labels: {
|
||||
severity: 'critical',
|
||||
severity: '%(nodeCriticalSeverity)s' % $._config,
|
||||
},
|
||||
annotations: {
|
||||
summary: 'Filesystem is predicted to run out of space within the next 4 hours.',
|
||||
|
@ -73,7 +73,7 @@
|
|||
||| % $._config,
|
||||
'for': '1h',
|
||||
labels: {
|
||||
severity: 'critical',
|
||||
severity: '%(nodeCriticalSeverity)s' % $._config,
|
||||
},
|
||||
annotations: {
|
||||
summary: 'Filesystem has less than 3% space left.',
|
||||
|
@ -113,7 +113,7 @@
|
|||
||| % $._config,
|
||||
'for': '1h',
|
||||
labels: {
|
||||
severity: 'critical',
|
||||
severity: '%(nodeCriticalSeverity)s' % $._config,
|
||||
},
|
||||
annotations: {
|
||||
summary: 'Filesystem is predicted to run out of inodes within the next 4 hours.',
|
||||
|
@ -149,7 +149,7 @@
|
|||
||| % $._config,
|
||||
'for': '1h',
|
||||
labels: {
|
||||
severity: 'critical',
|
||||
severity: '%(nodeCriticalSeverity)s' % $._config,
|
||||
},
|
||||
annotations: {
|
||||
summary: 'Filesystem has less than 3% inodes left.',
|
||||
|
|
|
@ -17,6 +17,19 @@
|
|||
// them here, e.g. 'device!="tmpfs"'.
|
||||
diskDeviceSelector: '',
|
||||
|
||||
// Some of the alerts are meant to fire if a critical failure of a
|
||||
// node is imminent (e.g. the disk is about to run full). In a
|
||||
// true “cloud native” setup, failures of a single node should be
|
||||
// tolerated. Hence, even imminent failure of a single node is no
|
||||
// reason to create a paging alert. However, in practice there are
|
||||
// still many situations where operators like to get paged in time
|
||||
// before a node runs out of disk space. nodeCriticalSeverity can
|
||||
// be set to the desired severity for this kind of alerts. This
|
||||
// can even be templated to depend on labels of the node, e.g. you
|
||||
// could make this critical for traditional database masters but
|
||||
// just a warning for K8s nodes.
|
||||
nodeCriticalSeverity: 'critical',
|
||||
|
||||
grafana_prefix: '',
|
||||
},
|
||||
}
|
||||
|
|
Loading…
Reference in a new issue