{ _config+:: { // Selectors are inserted between {} in Prometheus queries. // Select the metrics coming from the node exporter. Note that all // the selected metrics are shown stacked on top of each other in // the 'USE Method / Cluster' dashboard. Consider disabling that // dashboard if mixing up all those metrics in the same dashboard // doesn't make sense (e.g. because they are coming from different // clusters). nodeExporterSelector: 'job="node"', // Select the fstype for filesystem-related queries. If left // empty, all filesystems are selected. If you have unusual // filesystem you don't want to include in dashboards and // alerting, you can exclude them here, e.g. 'fstype!="tmpfs"'. fsSelector: 'fstype!=""', // Select the device for disk-related queries. If left empty, all // devices are selected. If you have unusual devices you don't // want to include in dashboards and alerting, you can exclude // them here, e.g. 'device!="tmpfs"'. diskDeviceSelector: 'device!=""', // Some of the alerts are meant to fire if a critical failure of a // node is imminent (e.g. the disk is about to run full). In a // true “cloud native” setup, failures of a single node should be // tolerated. Hence, even imminent failure of a single node is no // reason to create a paging alert. However, in practice there are // still many situations where operators like to get paged in time // before a node runs out of disk space. nodeCriticalSeverity can // be set to the desired severity for this kind of alerts. This // can even be templated to depend on labels of the node, e.g. you // could make this critical for traditional database masters but // just a warning for K8s nodes. nodeCriticalSeverity: 'critical', // Available disk space (%) thresholds on which to trigger the // 'NodeFilesystemSpaceFillingUp' alerts. These alerts fire if the disk // usage grows in a way that it is predicted to run out in 4h or 1d // and if the provided thresholds have been reached right now. // In some cases you'll want to adjust these, e.g. by default Kubernetes // runs the image garbage collection when the disk usage reaches 85% // of its available space. In that case, you'll want to reduce the // critical threshold below to something like 14 or 15, otherwise // the alert could fire under normal node usage. fsSpaceFillingUpWarningThreshold: 40, fsSpaceFillingUpCriticalThreshold: 20, // Available disk space (%) thresholds on which to trigger the // 'NodeFilesystemAlmostOutOfSpace' alerts. fsSpaceAvailableCriticalThreshold: 5, fsSpaceAvailableWarningThreshold: 3, rateInterval: '5m', // Opt-in for multi-cluster support. showMultiCluster: false, clusterLabel: 'cluster', dashboardNamePrefix: 'Node Exporter / ', dashboardTags: ['node-exporter-mixin'], }, }