// Copyright 2015 The Prometheus Authors // Licensed under the Apache License, Version 2.0 (the "License"); // you may not use this file except in compliance with the License. // You may obtain a copy of the License at // // http://www.apache.org/licenses/LICENSE-2.0 // // Unless required by applicable law or agreed to in writing, software // distributed under the License is distributed on an "AS IS" BASIS, // WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. // See the License for the specific language governing permissions and // limitations under the License. //go:build !nocpu // +build !nocpu package collector import ( "fmt" "os" "path/filepath" "regexp" "strconv" "sync" "github.com/alecthomas/kingpin/v2" "github.com/go-kit/log" "github.com/go-kit/log/level" "github.com/prometheus/client_golang/prometheus" "github.com/prometheus/procfs" "github.com/prometheus/procfs/sysfs" "golang.org/x/exp/maps" "golang.org/x/exp/slices" ) type cpuCollector struct { fs procfs.FS cpu *prometheus.Desc cpuInfo *prometheus.Desc cpuFrequencyHz *prometheus.Desc cpuFlagsInfo *prometheus.Desc cpuBugsInfo *prometheus.Desc cpuGuest *prometheus.Desc cpuCoreThrottle *prometheus.Desc cpuPackageThrottle *prometheus.Desc cpuIsolated *prometheus.Desc logger log.Logger cpuStats map[int64]procfs.CPUStat cpuStatsMutex sync.Mutex isolatedCpus []uint16 cpuFlagsIncludeRegexp *regexp.Regexp cpuBugsIncludeRegexp *regexp.Regexp } // Idle jump back limit in seconds. const jumpBackSeconds = 3.0 var ( enableCPUGuest = kingpin.Flag("collector.cpu.guest", "Enables metric node_cpu_guest_seconds_total").Default("true").Bool() enableCPUInfo = kingpin.Flag("collector.cpu.info", "Enables metric cpu_info").Bool() flagsInclude = kingpin.Flag("collector.cpu.info.flags-include", "Filter the `flags` field in cpuInfo with a value that must be a regular expression").String() bugsInclude = kingpin.Flag("collector.cpu.info.bugs-include", "Filter the `bugs` field in cpuInfo with a value that must be a regular expression").String() jumpBackDebugMessage = fmt.Sprintf("CPU Idle counter jumped backwards more than %f seconds, possible hotplug event, resetting CPU stats", jumpBackSeconds) ) func init() { registerCollector("cpu", defaultEnabled, NewCPUCollector) } // NewCPUCollector returns a new Collector exposing kernel/system statistics. func NewCPUCollector(logger log.Logger) (Collector, error) { fs, err := procfs.NewFS(*procPath) if err != nil { return nil, fmt.Errorf("failed to open procfs: %w", err) } sysfs, err := sysfs.NewFS(*sysPath) if err != nil { return nil, fmt.Errorf("failed to open sysfs: %w", err) } isolcpus, err := sysfs.IsolatedCPUs() if err != nil { if !os.IsNotExist(err) { return nil, fmt.Errorf("Unable to get isolated cpus: %w", err) } level.Debug(logger).Log("msg", "Could not open isolated file", "error", err) } c := &cpuCollector{ fs: fs, cpu: nodeCPUSecondsDesc, cpuInfo: prometheus.NewDesc( prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "info"), "CPU information from /proc/cpuinfo.", []string{"package", "core", "cpu", "vendor", "family", "model", "model_name", "microcode", "stepping", "cachesize"}, nil, ), cpuFrequencyHz: prometheus.NewDesc( prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "frequency_hertz"), "CPU frequency in hertz from /proc/cpuinfo.", []string{"package", "core", "cpu"}, nil, ), cpuFlagsInfo: prometheus.NewDesc( prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "flag_info"), "The `flags` field of CPU information from /proc/cpuinfo taken from the first core.", []string{"flag"}, nil, ), cpuBugsInfo: prometheus.NewDesc( prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "bug_info"), "The `bugs` field of CPU information from /proc/cpuinfo taken from the first core.", []string{"bug"}, nil, ), cpuGuest: prometheus.NewDesc( prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "guest_seconds_total"), "Seconds the CPUs spent in guests (VMs) for each mode.", []string{"cpu", "mode"}, nil, ), cpuCoreThrottle: prometheus.NewDesc( prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "core_throttles_total"), "Number of times this CPU core has been throttled.", []string{"package", "core"}, nil, ), cpuPackageThrottle: prometheus.NewDesc( prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "package_throttles_total"), "Number of times this CPU package has been throttled.", []string{"package"}, nil, ), cpuIsolated: prometheus.NewDesc( prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "isolated"), "Whether each core is isolated, information from /sys/devices/system/cpu/isolated.", []string{"cpu"}, nil, ), logger: logger, isolatedCpus: isolcpus, cpuStats: make(map[int64]procfs.CPUStat), } err = c.compileIncludeFlags(flagsInclude, bugsInclude) if err != nil { return nil, fmt.Errorf("fail to compile --collector.cpu.info.flags-include and --collector.cpu.info.bugs-include, the values of them must be regular expressions: %w", err) } return c, nil } func (c *cpuCollector) compileIncludeFlags(flagsIncludeFlag, bugsIncludeFlag *string) error { if (*flagsIncludeFlag != "" || *bugsIncludeFlag != "") && !*enableCPUInfo { *enableCPUInfo = true level.Info(c.logger).Log("msg", "--collector.cpu.info has been set to `true` because you set the following flags, like --collector.cpu.info.flags-include and --collector.cpu.info.bugs-include") } var err error if *flagsIncludeFlag != "" { c.cpuFlagsIncludeRegexp, err = regexp.Compile(*flagsIncludeFlag) if err != nil { return err } } if *bugsIncludeFlag != "" { c.cpuBugsIncludeRegexp, err = regexp.Compile(*bugsIncludeFlag) if err != nil { return err } } return nil } // Update implements Collector and exposes cpu related metrics from /proc/stat and /sys/.../cpu/. func (c *cpuCollector) Update(ch chan<- prometheus.Metric) error { if *enableCPUInfo { if err := c.updateInfo(ch); err != nil { return err } } if err := c.updateStat(ch); err != nil { return err } if c.isolatedCpus != nil { c.updateIsolated(ch) } return c.updateThermalThrottle(ch) } // updateInfo reads /proc/cpuinfo func (c *cpuCollector) updateInfo(ch chan<- prometheus.Metric) error { info, err := c.fs.CPUInfo() if err != nil { return err } for _, cpu := range info { ch <- prometheus.MustNewConstMetric(c.cpuInfo, prometheus.GaugeValue, 1, cpu.PhysicalID, cpu.CoreID, strconv.Itoa(int(cpu.Processor)), cpu.VendorID, cpu.CPUFamily, cpu.Model, cpu.ModelName, cpu.Microcode, cpu.Stepping, cpu.CacheSize) } cpuFreqEnabled, ok := collectorState["cpufreq"] if !ok || cpuFreqEnabled == nil { level.Debug(c.logger).Log("cpufreq key missing or nil value in collectorState map", err) } else if !*cpuFreqEnabled { for _, cpu := range info { ch <- prometheus.MustNewConstMetric(c.cpuFrequencyHz, prometheus.GaugeValue, cpu.CPUMHz*1e6, cpu.PhysicalID, cpu.CoreID, strconv.Itoa(int(cpu.Processor))) } } if len(info) != 0 { cpu := info[0] if err := updateFieldInfo(cpu.Flags, c.cpuFlagsIncludeRegexp, c.cpuFlagsInfo, ch); err != nil { return err } if err := updateFieldInfo(cpu.Bugs, c.cpuBugsIncludeRegexp, c.cpuBugsInfo, ch); err != nil { return err } } return nil } func updateFieldInfo(valueList []string, filter *regexp.Regexp, desc *prometheus.Desc, ch chan<- prometheus.Metric) error { if filter == nil { return nil } for _, val := range valueList { if !filter.MatchString(val) { continue } ch <- prometheus.MustNewConstMetric(desc, prometheus.GaugeValue, 1, val, ) } return nil } // updateThermalThrottle reads /sys/devices/system/cpu/cpu* and expose thermal throttle statistics. func (c *cpuCollector) updateThermalThrottle(ch chan<- prometheus.Metric) error { cpus, err := filepath.Glob(sysFilePath("devices/system/cpu/cpu[0-9]*")) if err != nil { return err } packageThrottles := make(map[uint64]uint64) packageCoreThrottles := make(map[uint64]map[uint64]uint64) // cpu loop for _, cpu := range cpus { // See // https://www.kernel.org/doc/Documentation/x86/topology.txt // https://www.kernel.org/doc/Documentation/cputopology.txt // https://www.kernel.org/doc/Documentation/ABI/testing/sysfs-devices-system-cpu var err error var physicalPackageID, coreID uint64 // topology/physical_package_id if physicalPackageID, err = readUintFromFile(filepath.Join(cpu, "topology", "physical_package_id")); err != nil { level.Debug(c.logger).Log("msg", "CPU is missing physical_package_id", "cpu", cpu) continue } // topology/core_id if coreID, err = readUintFromFile(filepath.Join(cpu, "topology", "core_id")); err != nil { level.Debug(c.logger).Log("msg", "CPU is missing core_id", "cpu", cpu) continue } // metric node_cpu_core_throttles_total // // We process this metric before the package throttles as there // are CPU+kernel combinations that only present core throttles // but no package throttles. // Seen e.g. on an Intel Xeon E5472 system with RHEL 6.9 kernel. if _, present := packageCoreThrottles[physicalPackageID]; !present { packageCoreThrottles[physicalPackageID] = make(map[uint64]uint64) } if _, present := packageCoreThrottles[physicalPackageID][coreID]; !present { // Read thermal_throttle/core_throttle_count only once if coreThrottleCount, err := readUintFromFile(filepath.Join(cpu, "thermal_throttle", "core_throttle_count")); err == nil { packageCoreThrottles[physicalPackageID][coreID] = coreThrottleCount } else { level.Debug(c.logger).Log("msg", "CPU is missing core_throttle_count", "cpu", cpu) } } // metric node_cpu_package_throttles_total if _, present := packageThrottles[physicalPackageID]; !present { // Read thermal_throttle/package_throttle_count only once if packageThrottleCount, err := readUintFromFile(filepath.Join(cpu, "thermal_throttle", "package_throttle_count")); err == nil { packageThrottles[physicalPackageID] = packageThrottleCount } else { level.Debug(c.logger).Log("msg", "CPU is missing package_throttle_count", "cpu", cpu) } } } for physicalPackageID, packageThrottleCount := range packageThrottles { ch <- prometheus.MustNewConstMetric(c.cpuPackageThrottle, prometheus.CounterValue, float64(packageThrottleCount), strconv.FormatUint(physicalPackageID, 10)) } for physicalPackageID, coreMap := range packageCoreThrottles { for coreID, coreThrottleCount := range coreMap { ch <- prometheus.MustNewConstMetric(c.cpuCoreThrottle, prometheus.CounterValue, float64(coreThrottleCount), strconv.FormatUint(physicalPackageID, 10), strconv.FormatUint(coreID, 10)) } } return nil } // updateIsolated reads /sys/devices/system/cpu/isolated through sysfs and exports isolation level metrics. func (c *cpuCollector) updateIsolated(ch chan<- prometheus.Metric) { for _, cpu := range c.isolatedCpus { cpuNum := strconv.Itoa(int(cpu)) ch <- prometheus.MustNewConstMetric(c.cpuIsolated, prometheus.GaugeValue, 1.0, cpuNum) } } // updateStat reads /proc/stat through procfs and exports CPU-related metrics. func (c *cpuCollector) updateStat(ch chan<- prometheus.Metric) error { stats, err := c.fs.Stat() if err != nil { return err } c.updateCPUStats(stats.CPU) // Acquire a lock to read the stats. c.cpuStatsMutex.Lock() defer c.cpuStatsMutex.Unlock() for cpuID, cpuStat := range c.cpuStats { cpuNum := strconv.Itoa(int(cpuID)) ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.User, cpuNum, "user") ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Nice, cpuNum, "nice") ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.System, cpuNum, "system") ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Idle, cpuNum, "idle") ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Iowait, cpuNum, "iowait") ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.IRQ, cpuNum, "irq") ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.SoftIRQ, cpuNum, "softirq") ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Steal, cpuNum, "steal") if *enableCPUGuest { // Guest CPU is also accounted for in cpuStat.User and cpuStat.Nice, expose these as separate metrics. ch <- prometheus.MustNewConstMetric(c.cpuGuest, prometheus.CounterValue, cpuStat.Guest, cpuNum, "user") ch <- prometheus.MustNewConstMetric(c.cpuGuest, prometheus.CounterValue, cpuStat.GuestNice, cpuNum, "nice") } } return nil } // updateCPUStats updates the internal cache of CPU stats. func (c *cpuCollector) updateCPUStats(newStats map[int64]procfs.CPUStat) { // Acquire a lock to update the stats. c.cpuStatsMutex.Lock() defer c.cpuStatsMutex.Unlock() // Reset the cache if the list of CPUs has changed. for i, n := range newStats { cpuStats := c.cpuStats[i] // If idle jumps backwards by more than X seconds, assume we had a hotplug event and reset the stats for this CPU. if (cpuStats.Idle - n.Idle) >= jumpBackSeconds { level.Debug(c.logger).Log("msg", jumpBackDebugMessage, "cpu", i, "old_value", cpuStats.Idle, "new_value", n.Idle) cpuStats = procfs.CPUStat{} } if n.Idle >= cpuStats.Idle { cpuStats.Idle = n.Idle } else { level.Debug(c.logger).Log("msg", "CPU Idle counter jumped backwards", "cpu", i, "old_value", cpuStats.Idle, "new_value", n.Idle) } if n.User >= cpuStats.User { cpuStats.User = n.User } else { level.Debug(c.logger).Log("msg", "CPU User counter jumped backwards", "cpu", i, "old_value", cpuStats.User, "new_value", n.User) } if n.Nice >= cpuStats.Nice { cpuStats.Nice = n.Nice } else { level.Debug(c.logger).Log("msg", "CPU Nice counter jumped backwards", "cpu", i, "old_value", cpuStats.Nice, "new_value", n.Nice) } if n.System >= cpuStats.System { cpuStats.System = n.System } else { level.Debug(c.logger).Log("msg", "CPU System counter jumped backwards", "cpu", i, "old_value", cpuStats.System, "new_value", n.System) } if n.Iowait >= cpuStats.Iowait { cpuStats.Iowait = n.Iowait } else { level.Debug(c.logger).Log("msg", "CPU Iowait counter jumped backwards", "cpu", i, "old_value", cpuStats.Iowait, "new_value", n.Iowait) } if n.IRQ >= cpuStats.IRQ { cpuStats.IRQ = n.IRQ } else { level.Debug(c.logger).Log("msg", "CPU IRQ counter jumped backwards", "cpu", i, "old_value", cpuStats.IRQ, "new_value", n.IRQ) } if n.SoftIRQ >= cpuStats.SoftIRQ { cpuStats.SoftIRQ = n.SoftIRQ } else { level.Debug(c.logger).Log("msg", "CPU SoftIRQ counter jumped backwards", "cpu", i, "old_value", cpuStats.SoftIRQ, "new_value", n.SoftIRQ) } if n.Steal >= cpuStats.Steal { cpuStats.Steal = n.Steal } else { level.Debug(c.logger).Log("msg", "CPU Steal counter jumped backwards", "cpu", i, "old_value", cpuStats.Steal, "new_value", n.Steal) } if n.Guest >= cpuStats.Guest { cpuStats.Guest = n.Guest } else { level.Debug(c.logger).Log("msg", "CPU Guest counter jumped backwards", "cpu", i, "old_value", cpuStats.Guest, "new_value", n.Guest) } if n.GuestNice >= cpuStats.GuestNice { cpuStats.GuestNice = n.GuestNice } else { level.Debug(c.logger).Log("msg", "CPU GuestNice counter jumped backwards", "cpu", i, "old_value", cpuStats.GuestNice, "new_value", n.GuestNice) } c.cpuStats[i] = cpuStats } // Remove offline CPUs. if len(newStats) != len(c.cpuStats) { onlineCPUIds := maps.Keys(newStats) maps.DeleteFunc(c.cpuStats, func(key int64, item procfs.CPUStat) bool { return !slices.Contains(onlineCPUIds, key) }) } }