{ prometheusRules+:: { groups+: [ { name: 'node-exporter.rules', rules: [ { // This rule gives the number of CPUs per node. record: 'instance:node_num_cpu:sum', expr: ||| count without (cpu) ( count without (mode) ( node_cpu_seconds_total{%(nodeExporterSelector)s} ) ) ||| % $._config, }, { // CPU utilisation is % CPU is not idle. record: 'instance:node_cpu_utilisation:rate%(rateInterval)s' % $._config, expr: ||| 1 - avg without (cpu, mode) ( rate(node_cpu_seconds_total{%(nodeExporterSelector)s, mode="idle"}[%(rateInterval)s]) ) ||| % $._config, }, { // This is CPU saturation: 1min avg run queue length / number of CPUs. // Can go over 1. // TODO: There are situation where a run queue >1/core is just normal and fine. // We need to clarify how to read this metric and if its usage is helpful at all. record: 'instance:node_load1_per_cpu:ratio', expr: ||| ( node_load1{%(nodeExporterSelector)s} / instance:node_num_cpu:sum{%(nodeExporterSelector)s} ) ||| % $._config, }, { // Memory utilisation (ratio of used memory per instance). record: 'instance:node_memory_utilisation:ratio', expr: ||| 1 - ( node_memory_MemAvailable_bytes{%(nodeExporterSelector)s} / node_memory_MemTotal_bytes{%(nodeExporterSelector)s} ) ||| % $._config, }, { record: 'instance:node_vmstat_pgmajfault:rate%(rateInterval)s' % $._config, expr: ||| rate(node_vmstat_pgmajfault{%(nodeExporterSelector)s}[%(rateInterval)s]) ||| % $._config, }, { // Disk utilisation (seconds spent, 1 second rate). record: 'instance_device:node_disk_io_time_seconds:rate%(rateInterval)s' % $._config, expr: ||| rate(node_disk_io_time_seconds_total{%(nodeExporterSelector)s, %(diskDeviceSelector)s}[%(rateInterval)s]) ||| % $._config, }, { // Disk saturation (weighted seconds spent, 1 second rate). record: 'instance_device:node_disk_io_time_weighted_seconds:rate%(rateInterval)s' % $._config, expr: ||| rate(node_disk_io_time_weighted_seconds_total{%(nodeExporterSelector)s, %(diskDeviceSelector)s}[%(rateInterval)s]) ||| % $._config, }, { record: 'instance:node_network_receive_bytes_excluding_lo:rate%(rateInterval)s' % $._config, expr: ||| sum without (device) ( rate(node_network_receive_bytes_total{%(nodeExporterSelector)s, device!="lo"}[%(rateInterval)s]) ) ||| % $._config, }, { record: 'instance:node_network_transmit_bytes_excluding_lo:rate%(rateInterval)s' % $._config, expr: ||| sum without (device) ( rate(node_network_transmit_bytes_total{%(nodeExporterSelector)s, device!="lo"}[%(rateInterval)s]) ) ||| % $._config, }, // TODO: Find out if those drops ever happen on modern switched networks. { record: 'instance:node_network_receive_drop_excluding_lo:rate%(rateInterval)s' % $._config, expr: ||| sum without (device) ( rate(node_network_receive_drop_total{%(nodeExporterSelector)s, device!="lo"}[%(rateInterval)s]) ) ||| % $._config, }, { record: 'instance:node_network_transmit_drop_excluding_lo:rate%(rateInterval)s' % $._config, expr: ||| sum without (device) ( rate(node_network_transmit_drop_total{%(nodeExporterSelector)s, device!="lo"}[%(rateInterval)s]) ) ||| % $._config, }, ], }, ], }, }