prometheusAlerts+:: {
|
|
groups+: [
|
|
{
|
|
name: 'node-exporter',
|
|
rules: [
|
|
{
|
|
alert: 'NodeFilesystemSpaceFillingUp',
|
|
expr: |||
|
|
(
|
|
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s} * 100 < %(fsSpaceFillingUpWarningThreshold)d
|
|
and
|
|
predict_linear(node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s}[6h], 24*60*60) < 0
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem is predicted to run out of space within the next 24 hours.',
|
|
description: 'Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemSpaceFillingUp',
|
|
expr: |||
|
|
(
|
|
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s} * 100 < %(fsSpaceFillingUpCriticalThreshold)d
|
|
and
|
|
predict_linear(node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s}[6h], 4*60*60) < 0
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: '%(nodeCriticalSeverity)s' % $._config,
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem is predicted to run out of space within the next 4 hours.',
|
|
description: 'Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up fast.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemAlmostOutOfSpace',
|
|
expr: |||
|
|
(
|
|
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s} * 100 < %(fsSpaceAvailableCriticalThreshold)d
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem has less than %(fsSpaceAvailableCriticalThreshold)d%% space left.' % $._config,
|
|
description: 'Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemAlmostOutOfSpace',
|
|
expr: |||
|
|
(
|
|
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s} * 100 < %(fsSpaceAvailableWarningThreshold)d
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: '%(nodeCriticalSeverity)s' % $._config,
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem has less than %(fsSpaceAvailableWarningThreshold)d%% space left.' % $._config,
|
|
description: 'Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemFilesFillingUp',
|
|
expr: |||
|
|
(
|
|
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s} * 100 < 40
|
|
and
|
|
predict_linear(node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s}[6h], 24*60*60) < 0
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem is predicted to run out of inodes within the next 24 hours.',
|
|
description: 'Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemFilesFillingUp',
|
|
expr: |||
|
|
(
|
|
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s} * 100 < 20
|
|
and
|
|
predict_linear(node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s}[6h], 4*60*60) < 0
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: '%(nodeCriticalSeverity)s' % $._config,
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem is predicted to run out of inodes within the next 4 hours.',
|
|
description: 'Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up fast.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemAlmostOutOfFiles',
|
|
expr: |||
|
|
(
|
|
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s} * 100 < 5
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem has less than 5% inodes left.',
|
|
description: 'Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemAlmostOutOfFiles',
|
|
expr: |||
|
|
(
|
|
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s} * 100 < 3
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: '%(nodeCriticalSeverity)s' % $._config,
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem has less than 3% inodes left.',
|
|
description: 'Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeNetworkReceiveErrs',
|
|
expr: |||
|
|
rate(node_network_receive_errs_total[2m]) / rate(node_network_receive_packets_total[2m]) > 0.01
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Network interface is reporting many receive errors.',
|
|
description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} receive errors in the last two minutes.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeNetworkTransmitErrs',
|
|
expr: |||
|
|
rate(node_network_transmit_errs_total[2m]) / rate(node_network_transmit_packets_total[2m]) > 0.01
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Network interface is reporting many transmit errors.',
|
|
description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} transmit errors in the last two minutes.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeHighNumberConntrackEntriesUsed',
|
|
expr: |||
|
|
(node_nf_conntrack_entries / node_nf_conntrack_entries_limit) > 0.75
|
|
||| % $._config,
|
|
annotations: {
|
|
summary: 'Number of conntrack are getting close to the limit.',
|
|
description: '{{ $value | humanizePercentage }} of conntrack entries are used.',
|
|
},
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeTextFileCollectorScrapeError',
|
|
expr: |||
|
|
node_textfile_scrape_error{%(nodeExporterSelector)s} == 1
|
|
||| % $._config,
|
|
annotations: {
|
|
summary: 'Node Exporter text file collector failed to scrape.',
|
|
description: 'Node Exporter text file collector failed to scrape.',
|
|
},
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeClockSkewDetected',
|
|
expr: |||
|
|
(
|
|
node_timex_offset_seconds > 0.05
|
|
and
|
|
deriv(node_timex_offset_seconds[5m]) >= 0
|
|
)
|
|
or
|
|
(
|
|
node_timex_offset_seconds < -0.05
|
|
and
|
|
deriv(node_timex_offset_seconds[5m]) <= 0
|
|
)
|
|
||| % $._config,
|
|
'for': '10m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Clock skew detected.',
|
|
message: 'Clock on {{ $labels.instance }} is out of sync by more than 300s. Ensure NTP is configured correctly on this host.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeClockNotSynchronising',
|
|
expr: |||
|
|
min_over_time(node_timex_sync_status[5m]) == 0
|
|
and
|
|
node_timex_maxerror_seconds >= 16
|
|
||| % $._config,
|
|
'for': '10m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Clock not synchronising.',
|
|
message: 'Clock on {{ $labels.instance }} is not synchronising. Ensure NTP is configured on this host.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeRAIDDegraded',
|
|
expr: |||
|
|
node_md_disks_required - ignoring (state) (node_md_disks{state="active"}) > 0
|
|
||| % $._config,
|
|
'for': '15m',
|
|
labels: {
|
|
severity: 'critical',
|
|
},
|
|
annotations: {
|
|
summary: 'RAID Array is degraded',
|
|
description: "RAID array '{{ $labels.device }}' on {{ $labels.instance }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.",
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeRAIDDiskFailure',
|
|
expr: |||
|
|
node_md_disks{state="failed"} > 0
|
|
||| % $._config,
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Failed device in RAID array',
|
|
description: "At least one device in RAID array on {{ $labels.instance }} failed. Array '{{ $labels.device }}' needs attention and possibly a disk swap.",
|
|
},
|
|
},
|
|
],
|
|
},
|
|
],
|
|
},
|
|
}
|