This affects the following alerts: - NodeFilesystemAlmostOutOfFiles - NodeFilesystemSpaceFillingUp - NodeFilesystemAlmostOutOfSpace - NodeFilesystemFilesFillingUp Each alert is actually two alerting rules, one for the warning level, and one for the critical level. However, the critical one can be set to emit as a warning by using $._config.nodeCriticalSeverity. When this is true, both alerting rules will generate alerts with an identical set of labels, which is an error when both alerts fire. We add an extra label to these alerting rules in order to differentiate between the two levels when $._config.nodeCriticalSeverity is set to `warning`. Signed-off-by: Justin Lei <lei.justin@gmail.com>
437 lines
20 KiB
Plaintext
437 lines
20 KiB
Plaintext
{
|
|
prometheusAlerts+:: {
|
|
groups+: [
|
|
{
|
|
name: 'node-exporter',
|
|
rules: [
|
|
{
|
|
alert: 'NodeFilesystemSpaceFillingUp',
|
|
expr: |||
|
|
(
|
|
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceFillingUpWarningThreshold)d
|
|
and
|
|
predict_linear(node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[%(fsSpaceFillingUpPredictionWindow)s], 24*60*60) < 0
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
window: '24h',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem is predicted to run out of space within the next 24 hours.',
|
|
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemSpaceFillingUp',
|
|
expr: |||
|
|
(
|
|
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceFillingUpCriticalThreshold)d
|
|
and
|
|
predict_linear(node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[6h], 4*60*60) < 0
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: '%(nodeCriticalSeverity)s' % $._config,
|
|
window: '4h',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem is predicted to run out of space within the next 4 hours.',
|
|
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up fast.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemAlmostOutOfSpace',
|
|
expr: |||
|
|
(
|
|
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceAvailableWarningThreshold)d
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '30m',
|
|
labels: {
|
|
severity: 'warning',
|
|
threshold: '%(fsSpaceAvailableWarningThreshold)d%%' % $._config,
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem has less than %(fsSpaceAvailableWarningThreshold)d%% space left.' % $._config,
|
|
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemAlmostOutOfSpace',
|
|
expr: |||
|
|
(
|
|
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceAvailableCriticalThreshold)d
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '30m',
|
|
labels: {
|
|
severity: '%(nodeCriticalSeverity)s' % $._config,
|
|
threshold: '%(fsSpaceAvailableCriticalThreshold)d%%' % $._config,
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem has less than %(fsSpaceAvailableCriticalThreshold)d%% space left.' % $._config,
|
|
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemFilesFillingUp',
|
|
expr: |||
|
|
(
|
|
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 40
|
|
and
|
|
predict_linear(node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[6h], 24*60*60) < 0
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
window: '24h',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem is predicted to run out of inodes within the next 24 hours.',
|
|
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemFilesFillingUp',
|
|
expr: |||
|
|
(
|
|
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 20
|
|
and
|
|
predict_linear(node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[6h], 4*60*60) < 0
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: '%(nodeCriticalSeverity)s' % $._config,
|
|
window: '4h',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem is predicted to run out of inodes within the next 4 hours.',
|
|
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up fast.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemAlmostOutOfFiles',
|
|
expr: |||
|
|
(
|
|
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 5
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
threshold: '5%',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem has less than 5% inodes left.',
|
|
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFilesystemAlmostOutOfFiles',
|
|
expr: |||
|
|
(
|
|
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 3
|
|
and
|
|
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
|
|
)
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: '%(nodeCriticalSeverity)s' % $._config,
|
|
threshold: '3%',
|
|
},
|
|
annotations: {
|
|
summary: 'Filesystem has less than 3% inodes left.',
|
|
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeNetworkReceiveErrs',
|
|
expr: |||
|
|
rate(node_network_receive_errs_total{%(nodeExporterSelector)s}[2m]) / rate(node_network_receive_packets_total{%(nodeExporterSelector)s}[2m]) > 0.01
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Network interface is reporting many receive errors.',
|
|
description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} receive errors in the last two minutes.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeNetworkTransmitErrs',
|
|
expr: |||
|
|
rate(node_network_transmit_errs_total{%(nodeExporterSelector)s}[2m]) / rate(node_network_transmit_packets_total{%(nodeExporterSelector)s}[2m]) > 0.01
|
|
||| % $._config,
|
|
'for': '1h',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Network interface is reporting many transmit errors.',
|
|
description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} transmit errors in the last two minutes.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeHighNumberConntrackEntriesUsed',
|
|
expr: |||
|
|
(node_nf_conntrack_entries{%(nodeExporterSelector)s} / node_nf_conntrack_entries_limit) > 0.75
|
|
||| % $._config,
|
|
annotations: {
|
|
summary: 'Number of conntrack are getting close to the limit.',
|
|
description: '{{ $value | humanizePercentage }} of conntrack entries are used.',
|
|
},
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeTextFileCollectorScrapeError',
|
|
expr: |||
|
|
node_textfile_scrape_error{%(nodeExporterSelector)s} == 1
|
|
||| % $._config,
|
|
annotations: {
|
|
summary: 'Node Exporter text file collector failed to scrape.',
|
|
description: 'Node Exporter text file collector on {{ $labels.instance }} failed to scrape.',
|
|
},
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeClockSkewDetected',
|
|
expr: |||
|
|
(
|
|
node_timex_offset_seconds{%(nodeExporterSelector)s} > 0.05
|
|
and
|
|
deriv(node_timex_offset_seconds{%(nodeExporterSelector)s}[5m]) >= 0
|
|
)
|
|
or
|
|
(
|
|
node_timex_offset_seconds{%(nodeExporterSelector)s} < -0.05
|
|
and
|
|
deriv(node_timex_offset_seconds{%(nodeExporterSelector)s}[5m]) <= 0
|
|
)
|
|
||| % $._config,
|
|
'for': '10m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Clock skew detected.',
|
|
description: 'Clock at {{ $labels.instance }} is out of sync by more than 0.05s. Ensure NTP is configured correctly on this host.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeClockNotSynchronising',
|
|
expr: |||
|
|
min_over_time(node_timex_sync_status{%(nodeExporterSelector)s}[5m]) == 0
|
|
and
|
|
node_timex_maxerror_seconds{%(nodeExporterSelector)s} >= 16
|
|
||| % $._config,
|
|
'for': '10m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Clock not synchronising.',
|
|
description: 'Clock at {{ $labels.instance }} is not synchronising. Ensure NTP is configured on this host.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeRAIDDegraded',
|
|
expr: |||
|
|
node_md_disks_required{%(nodeExporterSelector)s,%(diskDeviceSelector)s} - ignoring (state) (node_md_disks{state="active",%(nodeExporterSelector)s,%(diskDeviceSelector)s}) > 0
|
|
||| % $._config,
|
|
'for': '15m',
|
|
labels: {
|
|
severity: 'critical',
|
|
},
|
|
annotations: {
|
|
summary: 'RAID Array is degraded.',
|
|
description: "RAID array '{{ $labels.device }}' at {{ $labels.instance }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.",
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeRAIDDiskFailure',
|
|
expr: |||
|
|
node_md_disks{state="failed",%(nodeExporterSelector)s,%(diskDeviceSelector)s} > 0
|
|
||| % $._config,
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Failed device in RAID array.',
|
|
description: "At least one device in RAID array at {{ $labels.instance }} failed. Array '{{ $labels.device }}' needs attention and possibly a disk swap.",
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFileDescriptorLimit',
|
|
expr: |||
|
|
(
|
|
node_filefd_allocated{%(nodeExporterSelector)s} * 100 / node_filefd_maximum{%(nodeExporterSelector)s} > 70
|
|
)
|
|
||| % $._config,
|
|
'for': '15m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Kernel is predicted to exhaust file descriptors limit soon.',
|
|
description: 'File descriptors limit at {{ $labels.instance }} is currently at {{ printf "%.2f" $value }}%.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeFileDescriptorLimit',
|
|
expr: |||
|
|
(
|
|
node_filefd_allocated{%(nodeExporterSelector)s} * 100 / node_filefd_maximum{%(nodeExporterSelector)s} > 90
|
|
)
|
|
||| % $._config,
|
|
'for': '15m',
|
|
labels: {
|
|
severity: 'critical',
|
|
},
|
|
annotations: {
|
|
summary: 'Kernel is predicted to exhaust file descriptors limit soon.',
|
|
description: 'File descriptors limit at {{ $labels.instance }} is currently at {{ printf "%.2f" $value }}%.',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeCPUHighUsage',
|
|
expr: |||
|
|
sum without(mode) (avg without (cpu) (rate(node_cpu_seconds_total{%(nodeExporterSelector)s, mode!="idle"}[2m]))) * 100 > %(cpuHighUsageThreshold)d
|
|
||| % $._config,
|
|
'for': '15m',
|
|
labels: {
|
|
severity: 'info',
|
|
},
|
|
annotations: {
|
|
summary: 'High CPU usage.',
|
|
description: |||
|
|
CPU usage at {{ $labels.instance }} has been above %(cpuHighUsageThreshold)d%% for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}%%.
|
|
||| % $._config,
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeSystemSaturation',
|
|
expr: |||
|
|
node_load1{%(nodeExporterSelector)s}
|
|
/ count without (cpu, mode) (node_cpu_seconds_total{%(nodeExporterSelector)s, mode="idle"}) > %(systemSaturationPerCoreThreshold)d
|
|
||| % $._config,
|
|
'for': '15m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'System saturated, load per core is very high.',
|
|
description: |||
|
|
System load per core at {{ $labels.instance }} has been above %(systemSaturationPerCoreThreshold)d for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}.
|
|
This might indicate this instance resources saturation and can cause it becoming unresponsive.
|
|
||| % $._config,
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeMemoryMajorPagesFaults',
|
|
expr: |||
|
|
rate(node_vmstat_pgmajfault{%(nodeExporterSelector)s}[5m]) > %(memoryMajorPagesFaultsThreshold)d
|
|
||| % $._config,
|
|
'for': '15m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Memory major page faults are occurring at very high rate.',
|
|
description: |||
|
|
Memory major pages are occurring at very high rate at {{ $labels.instance }}, %(memoryMajorPagesFaultsThreshold)d major page faults per second for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}.
|
|
Please check that there is enough memory available at this instance.
|
|
||| % $._config,
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeMemoryHighUtilization',
|
|
expr: |||
|
|
100 - (node_memory_MemAvailable_bytes{%(nodeExporterSelector)s} / node_memory_MemTotal_bytes{%(nodeExporterSelector)s} * 100) > %(memoryHighUtilizationThreshold)d
|
|
||| % $._config,
|
|
'for': '15m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Host is running out of memory.',
|
|
description: |||
|
|
Memory is filling up at {{ $labels.instance }}, has been above %(memoryHighUtilizationThreshold)d%% for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}%%.
|
|
||| % $._config,
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeDiskIOSaturation',
|
|
expr: |||
|
|
rate(node_disk_io_time_weighted_seconds_total{%(nodeExporterSelector)s, %(diskDeviceSelector)s}[5m]) > %(diskIOSaturationThreshold)d
|
|
||| % $._config,
|
|
'for': '30m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Disk IO queue is high.',
|
|
description: |||
|
|
Disk IO queue (aqu-sq) is high on {{ $labels.device }} at {{ $labels.instance }}, has been above %(diskIOSaturationThreshold)d for the last 30 minutes, is currently at {{ printf "%%.2f" $value }}.
|
|
This symptom might indicate disk saturation.
|
|
||| % $._config,
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeSystemdServiceFailed',
|
|
expr: |||
|
|
node_systemd_unit_state{%(nodeExporterSelector)s, state="failed"} == 1
|
|
||| % $._config,
|
|
'for': '5m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Systemd service has entered failed state.',
|
|
description: 'Systemd service {{ $labels.name }} has entered failed state at {{ $labels.instance }}',
|
|
},
|
|
},
|
|
{
|
|
alert: 'NodeBondingDegraded',
|
|
expr: |||
|
|
(node_bonding_slaves - node_bonding_active) != 0
|
|
||| % $._config,
|
|
'for': '5m',
|
|
labels: {
|
|
severity: 'warning',
|
|
},
|
|
annotations: {
|
|
summary: 'Bonding interface is degraded',
|
|
description: 'Bonding interface {{ $labels.master }} on {{ $labels.instance }} is in degraded state due to one or more slave failures.',
|
|
},
|
|
},
|
|
],
|
|
},
|
|
],
|
|
},
|
|
}
|