node_exporter/docs/node-mixin/alerts/alerts.libsonnet
Taylor Sly 9f9473859b
Fix description for NodeDiskIOSaturation alert (#2929)
NodeDiskIOSaturation description should say 30m per the "for" clause

Signed-off-by: Taylor Sly <slyt@users.noreply.github.com>
2024-02-16 08:58:22 +01:00

429 lines
20 KiB
Plaintext

{
prometheusAlerts+:: {
groups+: [
{
name: 'node-exporter',
rules: [
{
alert: 'NodeFilesystemSpaceFillingUp',
expr: |||
(
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceFillingUpWarningThreshold)d
and
predict_linear(node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[%(fsSpaceFillingUpPredictionWindow)s], 24*60*60) < 0
and
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
)
||| % $._config,
'for': '1h',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Filesystem is predicted to run out of space within the next 24 hours.',
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up.',
},
},
{
alert: 'NodeFilesystemSpaceFillingUp',
expr: |||
(
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceFillingUpCriticalThreshold)d
and
predict_linear(node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[6h], 4*60*60) < 0
and
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
)
||| % $._config,
'for': '1h',
labels: {
severity: '%(nodeCriticalSeverity)s' % $._config,
},
annotations: {
summary: 'Filesystem is predicted to run out of space within the next 4 hours.',
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up fast.',
},
},
{
alert: 'NodeFilesystemAlmostOutOfSpace',
expr: |||
(
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceAvailableWarningThreshold)d
and
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
)
||| % $._config,
'for': '30m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Filesystem has less than %(fsSpaceAvailableWarningThreshold)d%% space left.' % $._config,
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.',
},
},
{
alert: 'NodeFilesystemAlmostOutOfSpace',
expr: |||
(
node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceAvailableCriticalThreshold)d
and
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
)
||| % $._config,
'for': '30m',
labels: {
severity: '%(nodeCriticalSeverity)s' % $._config,
},
annotations: {
summary: 'Filesystem has less than %(fsSpaceAvailableCriticalThreshold)d%% space left.' % $._config,
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.',
},
},
{
alert: 'NodeFilesystemFilesFillingUp',
expr: |||
(
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 40
and
predict_linear(node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[6h], 24*60*60) < 0
and
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
)
||| % $._config,
'for': '1h',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Filesystem is predicted to run out of inodes within the next 24 hours.',
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up.',
},
},
{
alert: 'NodeFilesystemFilesFillingUp',
expr: |||
(
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 20
and
predict_linear(node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[6h], 4*60*60) < 0
and
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
)
||| % $._config,
'for': '1h',
labels: {
severity: '%(nodeCriticalSeverity)s' % $._config,
},
annotations: {
summary: 'Filesystem is predicted to run out of inodes within the next 4 hours.',
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up fast.',
},
},
{
alert: 'NodeFilesystemAlmostOutOfFiles',
expr: |||
(
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 5
and
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
)
||| % $._config,
'for': '1h',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Filesystem has less than 5% inodes left.',
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.',
},
},
{
alert: 'NodeFilesystemAlmostOutOfFiles',
expr: |||
(
node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 3
and
node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0
)
||| % $._config,
'for': '1h',
labels: {
severity: '%(nodeCriticalSeverity)s' % $._config,
},
annotations: {
summary: 'Filesystem has less than 3% inodes left.',
description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.',
},
},
{
alert: 'NodeNetworkReceiveErrs',
expr: |||
rate(node_network_receive_errs_total{%(nodeExporterSelector)s}[2m]) / rate(node_network_receive_packets_total{%(nodeExporterSelector)s}[2m]) > 0.01
||| % $._config,
'for': '1h',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Network interface is reporting many receive errors.',
description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} receive errors in the last two minutes.',
},
},
{
alert: 'NodeNetworkTransmitErrs',
expr: |||
rate(node_network_transmit_errs_total{%(nodeExporterSelector)s}[2m]) / rate(node_network_transmit_packets_total{%(nodeExporterSelector)s}[2m]) > 0.01
||| % $._config,
'for': '1h',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Network interface is reporting many transmit errors.',
description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} transmit errors in the last two minutes.',
},
},
{
alert: 'NodeHighNumberConntrackEntriesUsed',
expr: |||
(node_nf_conntrack_entries{%(nodeExporterSelector)s} / node_nf_conntrack_entries_limit) > 0.75
||| % $._config,
annotations: {
summary: 'Number of conntrack are getting close to the limit.',
description: '{{ $value | humanizePercentage }} of conntrack entries are used.',
},
labels: {
severity: 'warning',
},
},
{
alert: 'NodeTextFileCollectorScrapeError',
expr: |||
node_textfile_scrape_error{%(nodeExporterSelector)s} == 1
||| % $._config,
annotations: {
summary: 'Node Exporter text file collector failed to scrape.',
description: 'Node Exporter text file collector on {{ $labels.instance }} failed to scrape.',
},
labels: {
severity: 'warning',
},
},
{
alert: 'NodeClockSkewDetected',
expr: |||
(
node_timex_offset_seconds{%(nodeExporterSelector)s} > 0.05
and
deriv(node_timex_offset_seconds{%(nodeExporterSelector)s}[5m]) >= 0
)
or
(
node_timex_offset_seconds{%(nodeExporterSelector)s} < -0.05
and
deriv(node_timex_offset_seconds{%(nodeExporterSelector)s}[5m]) <= 0
)
||| % $._config,
'for': '10m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Clock skew detected.',
description: 'Clock at {{ $labels.instance }} is out of sync by more than 0.05s. Ensure NTP is configured correctly on this host.',
},
},
{
alert: 'NodeClockNotSynchronising',
expr: |||
min_over_time(node_timex_sync_status{%(nodeExporterSelector)s}[5m]) == 0
and
node_timex_maxerror_seconds{%(nodeExporterSelector)s} >= 16
||| % $._config,
'for': '10m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Clock not synchronising.',
description: 'Clock at {{ $labels.instance }} is not synchronising. Ensure NTP is configured on this host.',
},
},
{
alert: 'NodeRAIDDegraded',
expr: |||
node_md_disks_required{%(nodeExporterSelector)s,%(diskDeviceSelector)s} - ignoring (state) (node_md_disks{state="active",%(nodeExporterSelector)s,%(diskDeviceSelector)s}) > 0
||| % $._config,
'for': '15m',
labels: {
severity: 'critical',
},
annotations: {
summary: 'RAID Array is degraded.',
description: "RAID array '{{ $labels.device }}' at {{ $labels.instance }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.",
},
},
{
alert: 'NodeRAIDDiskFailure',
expr: |||
node_md_disks{state="failed",%(nodeExporterSelector)s,%(diskDeviceSelector)s} > 0
||| % $._config,
labels: {
severity: 'warning',
},
annotations: {
summary: 'Failed device in RAID array.',
description: "At least one device in RAID array at {{ $labels.instance }} failed. Array '{{ $labels.device }}' needs attention and possibly a disk swap.",
},
},
{
alert: 'NodeFileDescriptorLimit',
expr: |||
(
node_filefd_allocated{%(nodeExporterSelector)s} * 100 / node_filefd_maximum{%(nodeExporterSelector)s} > 70
)
||| % $._config,
'for': '15m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Kernel is predicted to exhaust file descriptors limit soon.',
description: 'File descriptors limit at {{ $labels.instance }} is currently at {{ printf "%.2f" $value }}%.',
},
},
{
alert: 'NodeFileDescriptorLimit',
expr: |||
(
node_filefd_allocated{%(nodeExporterSelector)s} * 100 / node_filefd_maximum{%(nodeExporterSelector)s} > 90
)
||| % $._config,
'for': '15m',
labels: {
severity: 'critical',
},
annotations: {
summary: 'Kernel is predicted to exhaust file descriptors limit soon.',
description: 'File descriptors limit at {{ $labels.instance }} is currently at {{ printf "%.2f" $value }}%.',
},
},
{
alert: 'NodeCPUHighUsage',
expr: |||
sum without(mode) (avg without (cpu) (rate(node_cpu_seconds_total{%(nodeExporterSelector)s, mode!="idle"}[2m]))) * 100 > %(cpuHighUsageThreshold)d
||| % $._config,
'for': '15m',
labels: {
severity: 'info',
},
annotations: {
summary: 'High CPU usage.',
description: |||
CPU usage at {{ $labels.instance }} has been above %(cpuHighUsageThreshold)d%% for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}%%.
||| % $._config,
},
},
{
alert: 'NodeSystemSaturation',
expr: |||
node_load1{%(nodeExporterSelector)s}
/ count without (cpu, mode) (node_cpu_seconds_total{%(nodeExporterSelector)s, mode="idle"}) > %(systemSaturationPerCoreThreshold)d
||| % $._config,
'for': '15m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'System saturated, load per core is very high.',
description: |||
System load per core at {{ $labels.instance }} has been above %(systemSaturationPerCoreThreshold)d for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}.
This might indicate this instance resources saturation and can cause it becoming unresponsive.
||| % $._config,
},
},
{
alert: 'NodeMemoryMajorPagesFaults',
expr: |||
rate(node_vmstat_pgmajfault{%(nodeExporterSelector)s}[5m]) > %(memoryMajorPagesFaultsThreshold)d
||| % $._config,
'for': '15m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Memory major page faults are occurring at very high rate.',
description: |||
Memory major pages are occurring at very high rate at {{ $labels.instance }}, %(memoryMajorPagesFaultsThreshold)d major page faults per second for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}.
Please check that there is enough memory available at this instance.
||| % $._config,
},
},
{
alert: 'NodeMemoryHighUtilization',
expr: |||
100 - (node_memory_MemAvailable_bytes{%(nodeExporterSelector)s} / node_memory_MemTotal_bytes{%(nodeExporterSelector)s} * 100) > %(memoryHighUtilizationThreshold)d
||| % $._config,
'for': '15m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Host is running out of memory.',
description: |||
Memory is filling up at {{ $labels.instance }}, has been above %(memoryHighUtilizationThreshold)d%% for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}%%.
||| % $._config,
},
},
{
alert: 'NodeDiskIOSaturation',
expr: |||
rate(node_disk_io_time_weighted_seconds_total{%(nodeExporterSelector)s, %(diskDeviceSelector)s}[5m]) > %(diskIOSaturationThreshold)d
||| % $._config,
'for': '30m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Disk IO queue is high.',
description: |||
Disk IO queue (aqu-sq) is high on {{ $labels.device }} at {{ $labels.instance }}, has been above %(diskIOSaturationThreshold)d for the last 30 minutes, is currently at {{ printf "%%.2f" $value }}.
This symptom might indicate disk saturation.
||| % $._config,
},
},
{
alert: 'NodeSystemdServiceFailed',
expr: |||
node_systemd_unit_state{%(nodeExporterSelector)s, state="failed"} == 1
||| % $._config,
'for': '5m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Systemd service has entered failed state.',
description: 'Systemd service {{ $labels.name }} has entered failed state at {{ $labels.instance }}',
},
},
{
alert: 'NodeBondingDegraded',
expr: |||
(node_bonding_slaves - node_bonding_active) != 0
||| % $._config,
'for': '5m',
labels: {
severity: 'warning',
},
annotations: {
summary: 'Bonding interface is degraded',
description: 'Bonding interface {{ $labels.master }} on {{ $labels.instance }} is in degraded state due to one or more slave failures.',
},
},
],
},
],
},
}