node_exporter/docs/node-mixin/config.libsonnet
looklose 7d4103c089 chore: fix typo in comment
Signed-off-by: looklose <shishuaiqun@yeah.net>
2024-04-10 14:24:02 +02:00

97 lines
4.4 KiB
Plaintext

{
_config+:: {
// Selectors are inserted between {} in Prometheus queries.
// Select the metrics coming from the node exporter. Note that all
// the selected metrics are shown stacked on top of each other in
// the 'USE Method / Cluster' dashboard. Consider disabling that
// dashboard if mixing up all those metrics in the same dashboard
// doesn't make sense (e.g. because they are coming from different
// clusters).
nodeExporterSelector: 'job="node"',
// Select the fstype for filesystem-related queries. If left
// empty, all filesystems are selected. If you have unusual
// filesystem you don't want to include in dashboards and
// alerting, you can exclude them here, e.g. 'fstype!="tmpfs"'.
fsSelector: 'fstype!=""',
// Select the mountpoint for filesystem-related queries. If left
// empty, all mountpoints are selected. For example if you have a
// special purpose tmpfs instance that has a fixed size and will
// always be 100% full, but you still want alerts and dashboards for
// other tmpfs instances, you can exclude those by mountpoint prefix
// like so: 'mountpoint!~"/var/lib/foo.*"'.
fsMountpointSelector: 'mountpoint!=""',
// Select the device for disk-related queries. If left empty, all
// devices are selected. If you have unusual devices you don't
// want to include in dashboards and alerting, you can exclude
// them here, e.g. 'device!="tmpfs"'.
diskDeviceSelector: 'device!=""',
// Some of the alerts are meant to fire if a critical failure of a
// node is imminent (e.g. the disk is about to run full). In a
// true “cloud native” setup, failures of a single node should be
// tolerated. Hence, even imminent failure of a single node is no
// reason to create a paging alert. However, in practice there are
// still many situations where operators like to get paged in time
// before a node runs out of disk space. nodeCriticalSeverity can
// be set to the desired severity for this kind of alerts. This
// can even be templated to depend on labels of the node, e.g. you
// could make this critical for traditional database masters but
// just a warning for K8s nodes.
nodeCriticalSeverity: 'critical',
// CPU utilization (%) on which to trigger the
// 'NodeCPUHighUsage' alert.
cpuHighUsageThreshold: 90,
// Load average 1m (per core) on which to trigger the
// 'NodeSystemSaturation' alert.
systemSaturationPerCoreThreshold: 2,
// Available disk space (%) thresholds on which to trigger the
// 'NodeFilesystemSpaceFillingUp' alerts. These alerts fire if the disk
// usage grows in a way that it is predicted to run out in 4h or 1d
// and if the provided thresholds have been reached right now.
// In some cases you'll want to adjust these, e.g., by default, Kubernetes
// runs the image garbage collection when the disk usage reaches 85%
// of its available space. In that case, you'll want to reduce the
// critical threshold below to something like 14 or 15, otherwise
// the alert could fire under normal node usage.
// Additionally, the prediction window for the alert can be configured
// to account for environments where disk usage can fluctuate within
// a short time frame. By extending the prediction window, you can
// reduce false positives caused by temporary spikes, providing a
// more accurate prediction of disk space issues.
fsSpaceFillingUpWarningThreshold: 40,
fsSpaceFillingUpCriticalThreshold: 20,
fsSpaceFillingUpPredictionWindow: '6h',
// Available disk space (%) thresholds on which to trigger the
// 'NodeFilesystemAlmostOutOfSpace' alerts.
fsSpaceAvailableWarningThreshold: 5,
fsSpaceAvailableCriticalThreshold: 3,
// Memory utilization (%) level on which to trigger the
// 'NodeMemoryHighUtilization' alert.
memoryHighUtilizationThreshold: 90,
// Threshold for the rate of memory major page faults to trigger
// 'NodeMemoryMajorPagesFaults' alert.
memoryMajorPagesFaultsThreshold: 500,
// Disk IO queue level above which to trigger
// 'NodeDiskIOSaturation' alert.
diskIOSaturationThreshold: 10,
rateInterval: '5m',
// Opt-in for multi-cluster support.
showMultiCluster: false,
clusterLabel: 'cluster',
dashboardNamePrefix: 'Node Exporter / ',
dashboardTags: ['node-exporter-mixin'],
},
}