mirror of
https://github.com/prometheus/prometheus.git
synced 2025-01-12 22:37:27 -08:00
remove impl details from docs
Signed-off-by: mtfoley <mtfoley.mae@gmail.com>
This commit is contained in:
parent
00578d245b
commit
b6630876d3
|
@ -130,10 +130,7 @@ delta(cpu_temp_celsius{host="zeus"}[2h])
|
|||
|
||||
`deriv(v range-vector)` calculates the per-second derivative of the time series in a range
|
||||
vector `v`, using [simple linear regression](https://en.wikipedia.org/wiki/Simple_linear_regression).
|
||||
The range vector must have at least two samples in order to perform the calculation. The linear
|
||||
regression is used to calculate a slope and offset for a trend line, and the slope value is used
|
||||
for the derivative calculation. In order to reduce calculation errors, the timestamp of the first
|
||||
sample in the range vector is set as `x=0` within the linear regression algorithm. When `+Inf` or
|
||||
The range vector must have at least two samples in order to perform the calculation. When `+Inf` or
|
||||
`-Inf` are found in the range vector, the slope and offset value calculated will be `NaN`.
|
||||
|
||||
`deriv` should only be used with gauges.
|
||||
|
@ -335,11 +332,7 @@ January etc.
|
|||
`t` seconds from now, based on the range vector `v`, using [simple linear
|
||||
regression](https://en.wikipedia.org/wiki/Simple_linear_regression).
|
||||
The range vector must have at least two samples in order to perform the
|
||||
calculation. The linear regression is used to calculate a slope and offset
|
||||
for a trend line, and the slope and offset are used to calculate the predict
|
||||
the value of the time series. In order to reduce calculation errors, the
|
||||
timestamp of the first sample in the range vector is set as `x=0` within the
|
||||
linear regression algorithm. When `+Inf` or `-Inf` are found in the range vector,
|
||||
calculation. When `+Inf` or `-Inf` are found in the range vector,
|
||||
the slope and offset value calculated will be `NaN`.
|
||||
|
||||
`predict_linear` should only be used with gauges.
|
||||
|
|