## Flash Firmware
2022-11-04 10:06:45 -07:00
Download and unzip the latest firmware from [Meshtastic Downloads](https://meshtastic.org/downloads).
1. Connect your device to your computer with a USB data cable.
2. Double click the reset button on your device (this will put it into bootloader mode)
2022-11-04 10:06:45 -07:00
3. Notice a new drive will be mounted on your computer (Windows, Mac, or Linux)
4. Open this drive and you should see three files: `CURRENT.UF2`, `INDEX.HTM`, and `INFO_UF2.TXT`
2023-09-18 18:33:16 -07:00
5. Drop the appropriate firmware file (`firmware-DEVICE_NAME-x.x.x-xxxxxxx.uf2`) from the release onto this drive.
Once the file has finished copying onto the drive, the device will reboot and install the Meshtastic firmware.
2023-01-21 09:32:24 -08:00
## Connect and Configure Device
After flashing the Meshtastic firmware to the device, you can proceed with the initial configuration.
<div className="indexCtasBody">
<Link
className={"button button--outline button--lg cta--button"}
to={"/docs/getting-started/initial-config"}
>
Connect and Configure Device
</Link>
</div>
2023-05-03 07:45:41 -07:00
2023-05-03 07:47:36 -07:00
### Potential Flashing Edge Cases
2023-05-03 07:45:41 -07:00
:::info
Before flashing confirm that you have [RAK4631](https://docs.rakwireless.com/Product-Categories/WisBlock/RAK4631/) and not a [RAK4631-R](https://docs.rakwireless.com/Product-Categories/WisBlock/RAK4631-R/) If this is not the case, fear not. The hardware is identical but requires changing the bootloader. Instructions on how to do this are located [here](/docs/getting-started/flashing-firmware/nrf52/convert-rak4631r).
:::
:::info
Previous versions of the Meshtastic firmware may save stale data, causing devices to get stuck in a crash loop during startup. If you experience issues when upgrading your nRF52 device from a previous version of Meshtastic, you may need to perform a full factory reset of the internal flash memory.
Follow the guide to [factory erase your nRF52](/docs/getting-started/flashing-firmware/nrf52/nrf52-erase) device before continuing to [flash firmware](#flash-firmware).
:::