Settings

Setting Acceptable Values Default Description
environmental_measurement_plugin_measurement_enabled true, false false Enables the plugin.
environmental_measurement_plugin_display_farenheit true, false false We'll always read the sensor in Celsius, but sometimes we might want to display the results in Farenheit as a "user preference".
environmental_measurement_plugin_read_error_count_threshold integer 0 Sometimes sensor reads can fail. If this happens, we will retry a configurable number of attempts Each attempt will be delayed by the minimum required refresh rate for that sensor
environmental_measurement_plugin_recovery_interval integer (seconds) 0 Sometimes we can end up with more than read_error_count_threshold failures. In this case, we will stop trying to read from the sensor for a while. Wait this long until trying to read from the sensor again
environmental_measurement_plugin_screen_enabled true, false 0 Enable/Disable the environmental measurement plugin on-device display
environmental_measurement_plugin_sensor_pin integer 0 Specify the preferred GPIO Pin for sensor readings
environmental_measurement_plugin_sensor_type DHT11 0 Specify the sensor type
environmental_measurement_plugin_update_interval integer (seconds) 0 Interval in seconds of how often we should try to send our measurements to the mesh