mirror of
https://github.com/meshtastic/meshtastic.git
synced 2024-12-28 23:19:47 -08:00
2.3 KiB
2.3 KiB
id | title | sidebar_label |
---|---|---|
environment-plugin | Environment measurement | Environment measurement |
About
The Environment Measurement Plugin will allow nodes to send a specific message with information from connected environmental sensors. Currently supported sensors are DHT11 and Dallas 1-wire DS18B20. This plugin does only work on ESP32 devices.
Configuration
These are the settings that can be configured.
environmental_measurement_plugin_enabled
Is the plugin enabled?
0 = Disabled (Default)
1 = Enabled
environmental_measurement_plugin_screen_enabled
Show received sensor readings on device screen.
0 = Disabled (Default)
1 = Enabled
environmental_measurement_plugin_read_error_count_threshold
Error count threshold for failed sensor readings.
Default = 0
preferences.environmental_measurement_plugin_update_interval
How often (in seconds) should sensor readings be broadcasted?
Default = 0
environmental_measurement_plugin_recovery_interval
For how long should we wait (in seconds) before trying to read sensors again upon exceeded error threshold?
Default = 0
environmental_measurement_plugin_display_fahrenheit
Should temperature readings be converted to fahrenheit?
0 = Disabled (Default)
1 = Enabled
environmental_measurement_plugin_sensor_type
What sensor is connected?
0 = DHT11 (Default)
1 = Dallas 1-wire DS18B20
environmental_measurement_plugin_sensor_pin
Which pin is the sensor connected to?
Default = 0
Usage Notes
For basic usage, start with:
environmental_measurement_plugin_enabled = 1
environmental_measurement_plugin_screen_enabled = 1
Depending on which pin your sensor is connected to, set it accordingly:
environmental_measurement_plugin_sensor_pin = 13
:::note The device must be restarted after the settings have been changed for the plugin to take effect. :::
Hardware
The sensors can be wired differently, here's one example for sensor DS18B20 https://randomnerdtutorials.com/esp32-ds18b20-temperature-arduino-ide
Known Problems
- No default configuration values are currently set, so this must be done when enabling the plugin.