* Correctly cast Darwin memory info
* Cast stats to float64 before doing math on them to avoid integer
wrapping.
* Remove invalid `_total` suffix from gauge values.
* Handle counters in `meminfo.go`.
Signed-off-by: Ben Kochie <superq@gmail.com>
Fix typo on unit description of metric `*read_time_seconds_total` from milliseconds to seconds.
Signed-off-by: Marco Tulio R Braga <marco.tulio@mtulio.eng.br>
* If NRestarts or NRefused are not available, don't ignore the unit itself
* Don't report systemd metrics (NRestarts/NRefused) that are not available
Signed-off-by: James Hartig <james@getadmiral.com>
PIDs can vanish (exit) from /proc/ between gathering the list of PIDs
and getting all of their stats.
* Ignore file not found errors.
* Explicitly count the PIDs we find.
* Cleanup some error style issues.
Signed-off-by: Ben Kochie <superq@gmail.com>
* Replace supervisord xmlrpc library
* Use `github.com/mattn/go-xmlrpc` that doesn't leak goroutines.
* Fix uptime metric
* Use Prometheus best practices for uptime metric.
* Use "start time" rather than "uptime".
* Don't emit a start time if the process is down.
* Add changelog entry.
* Add example compatibility rules.
Signed-off-by: Ben Kochie <superq@gmail.com>
* vendor: Update prometheus/procfs
Signed-off-by: Hannes Körber <hannes.koerber@haktec.de>
* mountstats: Use new NFS protocol field
In https://github.com/prometheus/procfs/pull/100, the NFSTransportStats
struct was expanded by a field called protocol that specifies the NFS
protocol in use, either "tcp" or "udp". This commit adds the protocol as
a label to all NFS metrics exported via the mountstats collector.
Signed-off-by: Hannes Körber <hannes.koerber@haktec.de>
* Update fixtures for UDP mount
Signed-off-by: Hannes Körber <hannes.koerber@haktec.de>
It is quite common to put /var/lib/docker itself on a separate partition
and that should be monitored as well.
Signed-off-by: Johannes Wienke <languitar@semipol.de>
While the statfs(2) approach is reliable for normally mounted filesystems, the
flags returned can be inconsistent when filesystem has been remounted read-only
after encountering an error. The returned flags do accurately represent the
internal state of the filesystem, but they do not reflect whether the VFS layer
will accept writes. Instead, it makes sense to parse the current VFS mount
state from the options field in /proc/mounts since it takes precedence.
Signed-off-by: Brandon Gilmore <bgilmore@valvesoftware.com>
* add sys/class/net parsing from procfs and expose its metrics
Signed-off-by: Jan Klat <jenik@klatys.cz>
* change code to use int pointers per procfs change, move netclass to separate collector, change metric naming
Signed-off-by: Jan Klat <jenik@klatys.cz>
* bump year in licence, remove redundant newline, correct fixtures
Signed-off-by: Jan Klat <jenik@klatys.cz>
* fix style
Signed-off-by: Jan Klat <jenik@klatys.cz>
* change carrier changes to counter type
Signed-off-by: Jan Klat <jenik@klatys.cz>
* fix e2e output
Signed-off-by: Jan Klat <jenik@klatys.cz>
* add fixtures
Signed-off-by: Jan Klat <jenik@klatys.cz>
* update vendor, use fixtures correctly
Signed-off-by: Jan Klat <jenik@klatys.cz>
* change fixtures (device in /sys/class/net should be symlinked)
Signed-off-by: Jan Klat <jenik@klatys.cz>
* correct fixtures for 64k page, updated readme
Signed-off-by: Jan Klat <jenik@klatys.cz>
Fixed spelling mistakes.
Update transport_generic.go
Changed to a mutex approach instead of channels and added a timeout before declaring a mount stuck.
Removed unnecessary lock channel and clarified some var names.
Fixed style nits.
Signed-off-by: Mark Knapp <mknapp@hudson-trading.com>
* Add support for NRestarts counter introduced in systemd 235
`.service` units increment this counter any time the Restart= condition is
triggered.
Signed-off-by: Matthew McGinn <mamcgi@gmail.com>
* Send "Personality unknown" to debug, not info, remove unnecessary newline.
* Add support for "linear" personality.
* Always set number of active disks to 0 when a device is inactive.
* Add total disks calculation to unknown personalites.
Signed-off-by: Ben Kochie <superq@gmail.com>
* Fix for #945, cpu temperature is signed.
Added a type conversion to cpu temperature sysctl. Will still
collect/report -1 when the value is -1, this is because it should be up
to interpretation whether this is the correct value for the system or
not.
Some drivers will report -1 for cpu temperature. Other sensors will
report "an input into the fan control algorithm", i.e. not the actual
temperature, but how much fan it wants. Some people cool their machines
with liquid nitrogen.
Signed-off-by: Derek Marcotte <554b8425@razorfever.net>
* Do not rely on AArch64 CPUs to support 32-bit ARM for cross-testing.
Signed-off-by: Alexey Kopytov <akopytov@gmail.com>
* aarch64 like ppc64le reports 64k node_sockstat_TCP_mem_bytes due to 64k pages.
Signed-off-by: Alexey Kopytov <akopytov@gmail.com>
* cpu: Add a 2nd label 'package' to metric node_cpu_core_throttles_total
This commit fixes the node_cpu_core_throttles_total metrics on
multi-socket systems as the core_ids are the same for each package.
I.e. we need to count them seperately.
Rename the node_package_throttles_total metric label `node` to `package`.
Reorganize the sys.ttar archive and use the same symlinks as the Linux
kernel. Also, the new fixtures now use a dual-socket dual-core cpu w/o
HT/SMT (node0: cpu0+1, node1: cpu2+3) as well as processor-less
(memory-only) NUMA node 'node2' (this is a very rare case).
Signed-off-by: Karsten Weiss <knweiss@gmail.com>
* cpu: Use the direct /sys path to the cpu files.
Use the direct path /sys/devices/system/cpu/cpu[0-9]* (without symlinks)
instead of /sys/bus/cpu/devices/cpu[0-9]*.
The latter path also does not exist e.g. on RHEL 6.9's kernel.
Signed-off-by: Karsten Weiss <knweiss@gmail.com>
* cpu: Reverse core+package throttle processing order
Signed-off-by: Karsten Weiss <knweiss@gmail.com>
* cpu: Add documentation URLs
Signed-off-by: Karsten Weiss <knweiss@gmail.com>
Netstat is 40% of the metrics on my laptop, many of which
are highly detailed information about IP internals in the kernel.
~300 such metrics on every machine in your fleet is excessive,
so focus on key metrics by default, overridable by the user.
Fixes#515
Signed-off-by: Brian Brazil <brian.brazil@robustperception.io>
Vmstat has over 100 fields, most of which are highly
detailed debug information. Trim this down to only
essential fields by default, configurable by flag.
Signed-off-by: Brian Brazil <brian.brazil@robustperception.io>
* Only report core throttles per core, not per cpu
* Add topology/core_id to the cpu sysfs fixtures
* Add new cpu fixtures to ttar file
* Merge core_id reading and thermal throttle accounting
* Declare core_id
* updates for zfsonlinux 0.7.5
* add constants for KSTAT_DATA_* types
* added e2e test for negative values represented by uint64 that can result from ZFS bugs
Enable NFS client metrics by default now that it nolonger prints errors
on scrape if there are no metrics to display.
Also fixup the nfsd README to match the nfs entry.
All tools in OpenBSD base system use swpginuse instead of swpgonly
for reporting swap usage (snmpd, swapctl, top, vmstat), so let
memory collector use that as well for consistency.
* Add overlay to defIgnoredFSTypes
To avoid statfs() errors if node_exporter is running as non privileged user.
* Updated defIngoredFSTypes values in sorted order
* Update vendor github.com/prometheus/procfs/...
* Refactor NFS collector
Use new procfs library to parse NFS client stats.
* Ignore nfs proc file not existing.
* Refactor with reflection to walk the structs.
The node exporter runs unprivileged, so it cannot statfs any filesystems
under this directory causing log spam. In addition there tends to be
high churn in the filesystems here (as it's basically application
monitoring) which can cause high cardinaltiy and in one case caused
Prometheus's index symbol table to get very large.
Accordingly this should be ignored to reduce log spam and avoid
performance issues. The filesystems themselves can in principle be
monitored via container oriented exporters, and the underlying
filesystems will still be monitored.
* Unify CPU collector conventions
Add a common CPU metric description.
* All collectors use the same `nodeCpuSecondsDesc`.
* All collectors drop the `cpu` prefix for `cpu` label values.
* Fix subsystem string in cpu_freebsd.
* Fix Linux CPU freq label names.
* Improve stat linux metric names.
cpu is no longer used.
* node_cpu -> node_cpu_seconds_total for Linux
* Improve filesystem metric names with units
* Improve units and names of linux disk stats
Remove sector metrics, the bytes metrics cover those already.
* Infiniband counters should end in _total
* Improve timex metric names, convert to more normal units.
See
3c073991eb/kernel/time/ntp.c (L909)
for what stabil means, looks like a moving average of some form.
* Update test fixture
* For meminfo metrics that had "kB" units, add _bytes
* Interrupts counter should have _total
* Move FreeBSD/DragonflyBSD out of meminfo add kvm.
This gives us SwapUsed, and everything under one roof.
* Fix typos per review.
* Update to use newer API.
* Remove premature optimization per PR feedback.
* Implements meminfo collector for OpenBSD
This is a rework of #151.
* Fix CGO import
* Add some useful metrics
* Rename total -> size for normalization
* remove injection hook for textfile metrics, convert them to prometheus format
* add support for summaries
* add support for histograms
* add logic for handling inconsistent labels within a metric family for counter, gauge, untyped
* change logic for parsing the metrics textfile
* fix logic to adding missing labels
* Export time and error metrics for textfiles
* Add tests for new textfile collector, fix found bugs
* refactor Update() to split into smaller functions
* remove parseTextFiles(), fix import issue
* add mtime metric directly to channel, fix handling of mtime during testing
* rename variables related to labels
* refactor: add default case, remove if guard for metrics, remove extra loop and slice
* refactor: remove extra loop iterating over metric families
* test: add test case for different metric type, fix found bug
* test: add test for metrics with inconsistent labels
* test: add test for histogram
* test: add test for histogram with extra dimension
* test: add test for summary
* test: add test for summary with extra dimension
* remove unnecessary creation of protobuf
* nit: remove extra blank line
Linux "guest" metrics for VMs are already accounted for in node_cpu
`user` and `nice` metrics. Separate these into their own metric to
avoid duplication of data.
* cpu: Support processor-less (memory-only) NUMA nodes
Processor-less (memory-only) NUMA nodes exist e.g. in systems that use
Intel Optane drives for RAM expansion using Intel Memory Drive
Technology (IMDT).
IMDT RAM expansion supports two modes:
* "Unify Remote Memory domains": present a processor-less (memory-only)
NUMA domain, which is the default
* "Expand local memory domains": to expand each processor’s memory domain
with a portion of the memory made available by Optane and IMDT
This commit fixes a crash in the first case (when "cpulist" is empty).
Here's an example of such a system:
$ numastat -m|head -n5
Per-node system memory usage (in MBs):
Node 0 Node 1 Node 2 Total
--------------- --------------- --------------- ---------------
MemTotal 118239.56 130816.00 464384.00 713439.56
$ for i in {0..2}; do echo -n "$i: " ; cat /sys/bus/node/devices/node$i/cpulist ; done
0: 0-7,16-23
1: 8-15,24-31
2:
$ /opt/vsmp/bin/vsmpversion -vvv
Memory Drive Technology: 8.2.1455.74 (Sep 28 2017 13:09:59)
System configuration:
Boards: 3
1 x Proc. + I/O + Memory
2 x NVM devices (Intel SSDPED1K375GAQ)
Processors: 2, Cores: 16, Threads: 32
Intel(R) Xeon(R) CPU E5-2667 v4 @ 3.20GHz Stepping 01
Memory (MB): 713472 (of 977450), Cache: 251416, Private: 12562
1 x 249088MB [262036/ 678/12270]
1 x 232192MB [357707/125369/ 146] 82:00.0#1
1 x 232192MB [357707/125369/ 146] 83:00.0#1
* cpu: rename some variables (pkg => node)
* cpu: Use %v not %q in log.Debugf() format strings
* Update golang.org/x/sys/unix
This allows to use simplified string conversion of Utsname members.
* Simplify Utsname string conversion
Use Utsname from golang.org/x/sys/unix which contains byte array
instead of int8/uint8 array members. This allows to simplify the string
conversions of these members.
* Correct buffer_bytes > INT_MAX on BSD/amd64.
The sysctl vfs.bufspace returns either an int or a long, depending on
the value. Large values of vfs.bufspace will result in error messages
like:
couldn't get meminfo: cannot allocate memory
This will detect the returned data type, and cast appropriately.
* Added explicit length checks per feedback.
* Flatten Value() to make it easier to read.
* Simplify per feedback.
* Fix style.
* Doc updates.